If you turn it clockwise, the time gets longer.

· 

When you are changing the setting, use accurate cross screwdriver.

· 

In factory condition, it is set at the shortet time possible.

※ Contact your vendor or our second factory if you haveany questions about 

product or requirepost-sales service.

Leader of geared motor GGM CO.,LTD.

http://www.ggm.co.kr

Headquarters / 1st Factory

22, Gyeongin-ro 3beon-gil, Bucheon-si, 
Gyeonggi-do, Republic of Korea
TEL : 82-32-664-7790      FAX : 82-32-611-7791

Attached research institute / No. 2 factory

180, Oksan-ro, Bucheon-si, Gyeonggi-do,
Republic of Korea
TEL : 82-32-684-7791      FAX : 82-32-683-5059

LED flickering

· 

If torque that is greater that the rating is applied to the motor for motor

for more than 5 seconds or if the motor rotation direction changes quickly
or turns on/off.

LED on

· 

If there is a problem with motor feedback signal due to motor cable 

  disconnection and connector connection problem

· 

If load is being carried downwards or too much load is operated on

8-2. Alarm output

In the following case, control unit protection function gets turned on and 
alarm out gets also turned on (L-LEVEL). Then, the motor stops. In this
case,it is shown with LED light on or off. Check the protection details.

※ When you are providing power, if the LED light turns on instantaneously,
    that is not a sign of malfunctioning.

Item

Hall sensor alarm

Over load alarm

Over heat alarm

Over voltage alarm

Over current alarm

Normality

LED sign

Flickering 1 times at 6 seconds intervals (Red)

Flickering 3 times at 6 seconds intervals (Red)

Flickering 5 times at 6 seconds intervals (Red)

Flickering 6 times at 6 seconds intervals (Red)

Flickering 8 times at 6 seconds intervals (Red)

Green light on ( Power )

Note

Motor stop

9-1. Slow start

9. Acceleration / Deceleration control

Motor response speed can be set between 0.5~10 seconds (at 3000rpm)

9-2. Slow stop

If you are stopping motor from outside, you can set the motor stopping 

time time at 0.5-10 seconds (at 3000rpm)

· 

When you extend input/output signal cable, do it for less than 2m. Try

  to make it as short as possible to minimize noise.

· 

input/output signal cable should be separated from power cable and

  motor cable.

When you access by following the direction above, alarm output will be 
off when control unit is (H-LEVEL) and on when control unit is(L-LEVEL),
stop the motor and turn off the control unit.
If there is no problem with motor cable, check other use conditions (load
torque, operation pattern and power voltage) Remove the reasons of 
protection mode and reapply power to reset alarm output

10. How to install communication module

Open the control case

Switch change

Install 485 communication module

1. Please release the lock point
    on the side of the product
    and slide the case to 
    separate it.

2. Change the switch to right.

3. Install the communication
    module in opposite side.

1

2

3