1. Confirmation when the product is handed over
1) Controller --------------------------- One
2) Power cable ----------------------------- One
3) External operation cable ------------------- One
In using and operating the product, be sure to observe the following
precautions. Failure to observe the precautions may result in electric
shock, injury or fire. The following precautions are very important and
should be observed at all times.
3. Caution at use
1. Confirm whether product is same with order.
2. Use in the places where ambient temperature range is -10℃ ~ +40℃
and humidity is 85% or less.
Also, avoid the place where reaches direct ray of light, and should install
COVER etc. when use adove places.
3. Avoid the places where there are a lot of dust, vibrations, and occurring
flammable gases, corrosive gases.
4. The rear of the controller has an active part.
Install in a box to prevent others from touching it easily.
5. Never put flammables around the motor and controller.
6. Do not use in places where a large amount of static electricity is
generated.
7. Install an overcurrent protection device, earth leakage breaker, and
overtemperature protection device for safety.
■ Caution for installation
1. If do parallel operation with controlled devices in electric furnace of high
capacity, THYRISTOR for welding machine, there may be occasion of
malfunction. Separate and wire by separate power circuit.
2. When do wiring CW-COM, CCW-COM for switching the direction at
wiring for external remote control, please be cateful not to be connected
CW-COM, CCW-COM terminals at the same time.
(when operate in state of connected CW-COM, CCW-COM both
terminals, there may be malfunction and can go hard on the motor.)
■ Wiring Precautions
Characteristic
- Slow start, slow down functions
- Easy connection, easy manipulation
Motor and wire get easily connected by just connecting speed control unit
connector.
Volume in front face can simply set up motor rotation speed.
- External control function
On/off, change of rotation direction and instant stop can be controlled through
outside signal (sequencer or relay signal).
Motor is maneuvered at the set accleration time and stopped at the set
deceleration time. This acceleration and deceleration times can be controlled
within 0.5~10 seconds.
2. Controller coding system
Product back
80
90 ± 0.5
52
Product front
90 ± 0.5
60
2-
Ø4.5HOLE
POWER
ALARM
SLOW
START
SLOW
STOP
Product side
100
80
1.5
11.5
113.5max.
102.5
2
GUB-U-30, GUB-U-60, GUB-U-90
GUB-C-30, GUB-C-60, GUB-C-90, GUB-C-150
GUB SERIES
Thank you for buying GGM products.
Before use this product, read well manual certainly and
understand all about knowledge, safety information and cautions
of product, and use right way. After read, please be sure to keep
fixed place to refer anytime.
Confirm following parts whether were equipped all.
In case of insufficient or was damaged, please contact our sales
representative or distributor.
SERIES
G SERIES
BLDC MOTOR
B
AC Input
CONTROLLER
TYPE
U
UNIT TYPE
G
U
B
C
60
SHAFT
U
1 100V 50/60Hz
Ø
1 110V 60Hz
Ø
1 115V 60Hz
Ø
C
1 200V 50/60Hz
Ø
1 220V 50/60Hz
Ø
1 230V 50/60Hz
Ø
OUTPUT
30
30W
60
60W
90
90W
150
150W
4. Specifications and appearance
Specification
Product name
Rating output
30
60
100 ~ 115
200 ~ 240
50 / 60 ( Allowawble range 5% )
90
90
150
Voltage
Frequency
GUB-U-30 GUB-U-60
GUB-C-30 GUB-C-60
GUB-U-90
GUB-C-90 GUB-C-150
W
V
Hz
A
A
Nㆍm
Nㆍm
r/min
r/min
P
O
W
E
R
I
N
P
U
T
1.0
2.5
0.1
0.15
1.5
3.5
0.2
0.3
2.5
5.0
0.3
0.5
0.6
2.0
0.1
0.15
3,000
100 ~ 3,000
RS485 (
optional
)
1.0
3.0
0.2
0.3
1.5
4
0.3
0.5
1.8
5
0.49
0.6
30
60
Rating torque
Starting torque
Rating rotation
speed
Speed control
range
Communication
Maximum
current
Rating
current