Installation Instructions

 

ELEKTROMAT 
SI 75.24-55,00

 

Model: 10002624 10011

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 06.03.2020

 

Pos: null /BA_Module/BA_Seitenumbruch @ 0\mod_1190719383361_0.docx @ 550 @  @ 1 

 

 

Содержание ELEKTROMAT SI 75.24-55,00

Страница 1: ... Deckblatt BAAA000001_M003 17 mod_1444211755814_28 docx 891110 1 Installation Instructions ELEKTROMAT SI 75 24 55 00 Model 10002624 10011 en Status 06 03 2020 Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 2: ...t BACA000001_M002 15 mod_1416821436083_28 docx 864410 1 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 D 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 3: ...8 Limit switch connection 14 9 Emergency manual operation emergency hand crank 15 10 Completion of commissioning testing 17 11 Declaration of incorporation Declaration of conformity 20 Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required ac...

Страница 4: ...nt of the manufacturer Otherwise the Manufacturer s Declaration shall be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the tasks assigned to them recognise potential danger zones and be able to take appropriate saf...

Страница 5: ...ing current 4 70 A Operating frequency 50 Hz Power factor cos φ 0 77 Maximum movement per hour 30 h 1 Hand forces 290 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow shaft 20 Braking torque spring loaded brake 20 Nm Braking voltage 103 130 V DC Rectifier type EGR 230 103 Temperature range 10 40 60 C Pos null BA_Module BA_FC Temperaturbereich BAFC000001_M00...

Страница 6: ...s and transmission elements must not be exceeded even for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter to the full Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions ...

Страница 7: ...7 Mounting Two elongated holes are provided for mounting Ⓐ Ⓑ Vertical installation is possible only when an additional torque mount is used Ⓑ ...

Страница 8: ...ions of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thoroughly grease the door shaft BAGAE03003_Z002 Mount the keys BAGAE03004_Z001 ...

Страница 9: ...t Version Ⓐ Tighten all connection elements M16 to 175 Nm Install all other connection elements according to the specifications of the door manufacturer Version Ⓑ Raise the pedestal bearing Install the torque mount Do not tighten yet ...

Страница 10: ...ive unit Version Ⓑ Tighten all connection elements M16 to 175 Nm Install all other connection elements according to the specifications of the door manufacturer Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 11: ...he cables are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the limit switch plug BAHAA03_Z001 BAHAC07_Z001 Completing the electrical installation Mount the cable entries and or cable glands Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0...

Страница 12: ...111_M001 0 mod_1194954682399_28 docx 2518 1 1 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 13: ...ion G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake Pos null BA_Module BA_MC Alternativer Motoranschluss BAMC011002_M001 0 mod_1271681188023_28 docx 518490 1 1 7 Alternative motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 14: ...126757070_28 docx 963 1 1 8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply network Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 15: ...Adopt a secure position For drive units with brake the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the d...

Страница 16: ...he crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 17: ...safety brake is triggered to prevent the door from dropping The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door against dropping Please observe the specifications of the door manufacturer The drive unit needs replacement Please observe the specification...

Страница 18: ... its equipment The manufacturer s specifications must be observed The brake release for doors without counter balancing may only be used in the CLOSE final limit position Warning Injury or danger to life possible Service life of the brake replacement of the entire brake in the case of Operation with mains supply after 250 000 door cycles Operation with frequency inverter after 1 000 000 door cycle...

Страница 19: ...tire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards Ende der Liste für Textmarke Inhalt ...

Страница 20: ...m in which it has been installed complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 ...