Table of contents 
1

 

General safety information .............................................................................................. 4

 

2

 

Technical Data ................................................................................................................ 5

 

3

 

Mechanical installation .................................................................................................... 6

 

4

 

Electrical installation ..................................................................................................... 10

 

5

 

Limit switch adjustment ................................................................................................. 11

 

6

 

Motor connection .......................................................................................................... 12

 

7

 

Alternative motor connection ......................................................................................... 12

 

8

 

Limit switch connection ................................................................................................. 13

 

9

 

Emergency manual operation (rapid hand chain operator) ............................................ 14

 

10

 

Completing commissioning / inspection ......................................................................... 16

 

11

 

Declaration of incorporation / Declaration of conformity ................................................. 17

 

 

 

 

 

  Symbols 

 

Warning - Potential injury or danger to life! 

 

Warning - Danger to life from electric current! 

 

Note - Important information! 

▶ 

Requirement - Required action! 

Schematic representations are based on product examples. Deviations from delivered 
products are possible. 

Содержание ELEKTROMAT SE 9.32-25,40

Страница 1: ...Installation Instructions ELEKTROMAT SE 9 32 25 40 RP09 32RD Model 10002729 10012 en Status 25 11 2019 ...

Страница 2: ...2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales gfa elektromaten co uk www gfa elektromaten co uk ...

Страница 3: ...connection 13 9 Emergency manual operation rapid hand chain operator 14 10 Completing commissioning inspection 16 11 Declaration of incorporation Declaration of conformity 17 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required action Schematic representations are based on product examples Deviations from de...

Страница 4: ...ll be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the tasks assigned to them recognise potential danger zones and be able to take appropriate safety measures The installation is only to be carried out with the su...

Страница 5: ... holding torque 450 Nm Maximum door weight 4000 N Supply voltage 3 400 V Operating current 1 20 A Operating frequency 50 Hz Power factor cos φ 0 87 Maximum movement per hour 16 h 1 Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow shaft 40 Temperature range 10 40 60 C 1 When using a temperature range of 40 60 C use half of maximum movements per hour ...

Страница 6: ... maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter to the full Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions BAGAC01001_ Z002 ...

Страница 7: ...7 Mounting Eight threads are provided for mounting Use at least 2 of these Keys are used to connect to the door shaft Use a key that is at least as long as the hollow shaft 8 x M8x16 BAGAD01001_Z002 ...

Страница 8: ...manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thoroughly grease the door shaft BAGAE01001_Z003 Mount the keys Observe possible variants Ⓐ or Ⓑ BAGAE01002_Z003 ...

Страница 9: ... BAGAE01003_Z003 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE01006_Z002 25 Nm Secure the keys version Ⓑ only BAGAE01007_Z002 ...

Страница 10: ...s are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the limit switch plug BAHAC13_Z001 Completing the electrical installation Mount the cable entries and or cable glands ...

Страница 11: ...11 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel ...

Страница 12: ...12 6 Motor connection M1 Motor X13 Motor plug 7 Alternative motor connection M1 Motor X13 Motor plug ...

Страница 13: ...13 8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply network ...

Страница 14: ...gency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the door to drop Adopt a secure position For drive units with br...

Страница 15: ...15 Switch on by pulling the red handle Open or close by pulling the chain Switch off by pulling the green handle ...

Страница 16: ...tion cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good electric contact Emergency manual operation Check the function with the power disconnected Perform the check only between the final limit positions Limit switch Check the final limit positions by opening and closing fully The safety area must not be approached Drive ...

Страница 17: ... complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 11 1 5 13...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...20 ...

Отзывы: