![GFA ELEKTROMAT 00024 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/gfa/elektromat-00024/elektromat-00024_installation-instructions-manual_2219457006.webp)
6
3
Mechanical installation
Prerequisites
The permissible loads on walls, fastenings, mountings and transmission elements must not
be exceeded, even for maximum holding torques or locking torques (▶ refer to technical
data).
Connection elements
▶
Self-locking connection
elements with a minimum
strength of 800 N/mm
2
(8.8) must be used.
▶
Utilize the hole diameter
to the full.
▶
Use adequately
dimensioned washers for
elongated holes.
BAGAB00002_Z002
BAGAB00003_Z002
3 : 1
Permissible mounting positions
BAGAC03301_Z002
Содержание ELEKTROMAT 00024
Страница 1: ...f Installation Instructions ELEKTROMAT ST 16 24 40 00 Model 10002992 00024 en Status 22 11 2019...
Страница 7: ...7 Mounting Four holes are provided for mounting BAGAD03301_Z002...
Страница 15: ...15...