background image

 

  

17 

  

Entire drive unit 

 

Note! 

 

 

Have the drive checked annually by a specialist. 

 

Shorter inspection interval for frequently used doors. 

 

Observe the applicable regulations and standards. 

 

=== Ende der Liste für Textmarke Inhalt === 

 

Содержание 10004459 10011

Страница 1: ...ckblatt BAAA000001_M003 17 mod_1444211755814_28 docx 891110 1 Installation Instructions ELEKTROMAT SI 15 140 FU 40 00 Model 10004459 10011 en Status 06 03 2020 Pos null BA_Module BA_Seitenumbruch 0 mo...

Страница 2: ...BACA000001_M002 15 mod_1416821436083_28 docx 864410 1 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de Pos null BA_Module BA_Seitenumbru...

Страница 3: ...nection 12 8 Emergency manual operation emergency hand crank 13 9 Completion of commissioning testing 15 10 Declaration of incorporation Declaration of conformity 18 Pos null BA_Module BA_Seitenumbruc...

Страница 4: ...t of the manufacturer Otherwise the Manufacturer s Declaration shall be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitter...

Страница 5: ...58 h 1 Hand forces 195 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow shaft 20 Braking torque 9 Nm Braking voltage 103 V DC Rectifier type FU Temperature ran...

Страница 6: ...nsmission elements must not be exceeded even for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800...

Страница 7: ...7 Mounting Two elongated holes are provided for mounting BAGAD03001_Z003...

Страница 8: ...ons of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carryin...

Страница 9: ...hten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE03010_Z002 75 Nm 8 8 8 8 8 8 8 8 Pos null BA_Module BA_Sei...

Страница 10: ...the cables are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the moto...

Страница 11: ...1_M001 2 mod_1303306898342_28 docx 654220 1 1 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel Pos null...

Страница 12: ...M1 Motor X13 Motor plug Y1 Brake Pos null BA_Module BA_NA Endschalteranschluss BANA101101_M001 0 mod_1245933330141_28 docx 243304 1 1 7 Limit switch connection S10 Manual operation X12 DES connection...

Страница 13: ...dopt a secure position For drive units with brake the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the per...

Страница 14: ...e crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361...

Страница 15: ...afety brake is triggered to prevent the door from dropping The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling...

Страница 16: ...its equipment The manufacturer s specifications must be observed The brake release for doors without counter balancing may only be used in the CLOSE final limit position Warning Injury or danger to li...

Страница 17: ...ire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards Ende der Liste f r Textmarke...

Страница 18: ...stalled complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signatur...

Страница 19: ...19...

Страница 20: ...20 Ende der Liste f r Textmarke Inhalt1...

Отзывы: