![GFA 10003371 00010 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/gfa/10003371-00010/10003371-00010_installation-instructions-manual_2219471013.webp)
13
5
Limit switch adjustment
Adjust the limit switches to define the final limits positions for OPEN and CLOSE.
Prerequisite
The door must open when the OPEN
pushbutton is operated. If the door closes, L1
and L2 must exchanged with the current
switched off.
Adjusting the OPEN limit position
Use the OPEN pushbutton to open the door
to the desired OPEN final limit position.
Rotate the cam of the OPEN limit switch S3
to the middle of tappet ①.
Tighten the screw of the cam ②.