GFA 10003248 00002 Скачать руководство пользователя страница 29

 

  

29 

 

 

16

 

Declaration of incorporation / Declaration of conformity 

Declaration of incorporation  

within the meaning of Machinery Directive 2006/42/EC 
for partly completed machinery, Appendix II Part B 
 

Declaration of conformity 

within the meaning of EMC Directive 2014/30/EU 
within the meaning of RoHS Directive 2011/65/EU 

We,  
GfA ELEKTROMATEN GmbH & Co. KG 
declare under our sole responsibility that the 
following product complies with the above 
directives and is only intended for installation in a 
door system. 
 
Drive unit 

SI 25.15-30,00 Ex 

Part no.: 10003248 00002 
 
 
We undertake to transmit in response to a 
reasoned request by the appropriate regulatory 
authorities the special documents on the partly 
completed machinery. 
 
This product must only be put into operation 
when it has been determined that the complete 
machine/system in which it has been installed 
complies with the provisions of the above-
mentioned directives. 
 
Authorised representative to compile the 
technical documents is the undersigned. 
 
Düsseldorf, 10.08.2018 
 
Stephan Kleine 
CEO 
 

 

Signature 
 
 

  The following requirements from Appendix I of 

the Machinery Directive 2006/42/EC are met: 
1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 
1.3.3, 1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.6, 1.5.7, 
1.5.8, 1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2, 
1.6.4, 1.7.2, 1.7.3, 1.7.4.3. 
 
Standards applied: 
EN 12453:2001 
Industrial, commercial and garage doors and 
gates - Safety in use of power operated doors - 
Requirements 
 
EN 12604:2017 
Industrial, commercial and garage doors and 
gates - Mechanical aspects - Requirements 
 
EN 60335-1:2012 
Household and similar electrical appliances - 
Safety - Part 1: General requirements 
 
EN 61000-6-2:2005 
Electromagnetic compatibility (EMC) Part 6-2 
Generic standards – Immunity standard for 
industrial environments 
 
EN 61000-6-3:2007 
Electromagnetic compatibility (EMC) Part 6-3 
Generic standards – Emission standard for 
residential, commercial and light-industrial 
environments 

 

 

 

  
 

Содержание 10003248 00002

Страница 1: ...f Installation Instructions ELEKTROMAT SI 25 15 30 00 Ex Model 10003248 00002 en Status 19 11 2019...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...tion of the motor 18 11 Limit switch connection 18 12 Emergency manual operation emergency hand crank 19 13 Completion of commissioning testing operation 21 14 Declaration of conformity Motor 26 15 De...

Страница 4: ...sks are to be performed by skilled personnel only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the tasks assigned to them recognise potential danger...

Страница 5: ...for frequency inverter operation 15 15 rpm Supply voltage 3 400 V Operating current 2 70 A Operating frequency 50 Hz Power factor cos 0 76 Maximum movements per hour 20 h 1 Manual force emergency manu...

Страница 6: ...85F 92 T4 Manufacturer GfA Explosion protection II 2G Ex h IIC T4 Gb II 2D Ex h IIIC 130 C Db Max output torque 400 Nm Max output speed 19 rpm Shaft centre distance 85 mm Transmission ratio 1 92 Tempe...

Страница 7: ...ting current 4 68 2 70 A Operating frequency 50 Hz Power 1 1 kW Power factor cos 0 76 Motor speed 1430 rpm Motor torque 7 3 Nm Operating mode S1 Protection class IP 65 Temperature class T4 PTC resisto...

Страница 8: ...6 20 40 T5 20 55 C Protection class IP 66 6 Technical data of limit switch emergency manual operation switch Type 07 2511 113061G Manufacturer Bartec Explosion protection II 2G Ex d IIC T6 II 2D Ex tD...

Страница 9: ...walls mountings connection and transmission elements must not be exceeded even for maximum holding or locking torque observe technical data Connection elements Use self locking connection elements wi...

Страница 10: ...10 Permissible mounting positions BAGAC03005_Z001 Mounting 2 elongated holes are provided for mounting BAGAD03001_Z003...

Страница 11: ...her defined The door manufacturer s specifications must also be observed Warning Injury or danger to life possible Use a lifting device with sufficient load carrying capacity for installation tasks Co...

Страница 12: ...ve unit BAGAE3007_Z001 Tighten all connection elements M12 with a torque of 75 Nm Install all further connection elements according to the specifications of the door manufacturer BAGAE03012_Z001 75 Nm...

Страница 13: ...ect the cables mains OFF and check that the supply is off Observe the applicable regulations and standards Ensure proper electrical connection Use suitable tools Carrying out the electrical installati...

Страница 14: ...meproof motors d it must be equipped with a separate evaluation unit The evaluation unit measures the temperature of the motor coil and deactivates the motor as soon as the preset temperature is excee...

Страница 15: ...that the flameproof enclosure is closed In order to achieve the required tightness the cable glands are equipped with different sealing inserts They are available for the following cable diameters 5...

Страница 16: ...by pressing the OPEN push button of the control If the door closes L1 and L2 must be swapped in a de energised state Setting of OPEN final limit position Open to the desired OPEN final limit position...

Страница 17: ...1 EMERGENCY OPEN limit switch is preset by the setting of the OPEN final limit position The door must stop without posing any risks should the rotating direction be incorrect or should there be a faul...

Страница 18: ...resistor R2 PTC resistor R3 PTC resistor Y1 Spring loaded brake 11 Limit switch connection S10 Manual operation X12 Terminal rail S1 Safety open limit switch S2 Safety close limit switch S3 Open limit...

Страница 19: ...the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604...

Страница 20: ...20 Plug in the crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated...

Страница 21: ...ires no maintenance or inspection Warning Danger of the door dropping In the case of a gearbox damage the internal safety brake is triggered to prevent the door from dropping The gearbox stalls Releas...

Страница 22: ...only between final limit positions Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Brake Warning Injury or danger to life...

Страница 23: ...adequately short intervals should these be unavoidable due to operation processes Performed cleaning tasks should be documented Note Have the drive checked annually by a specialist Shorter inspection...

Страница 24: ...ove directive and that no new hazards arise from their assembly The assembled modules are intended only for installation in a door system Drive unit SI 25 15 30 00 Ex Part no 10003248 00002 Consisting...

Страница 25: ...he product according to Directive II 2G Ex h IIC T4 Gb II 2D Ex h IIIC 130 C Db Notified body pursuant to Directive T V Nord Anlagetechnik GmbH Am T V 1 30519 Hannover Deutschland Registration number...

Страница 26: ...26 14 Declaration of conformity Motor...

Страница 27: ...27 15 Declaration of conformity Accessories...

Страница 28: ...28...

Страница 29: ...d complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...32...