background image

 

 

 

1

 

General safety information 

 
Specified normal use 
The drive unit is intended for horizontally operating sliding doors. 

 

The drive unit must be protected against moisture and aggressive environmental 
conditions (such as corrosive substances). The drive units are only suitable for indoor use. 
Appropriate protective measures must be taken for outdoor installation. The drive unit is 
not intended for hazardous areas. The values specified in the technical data of the drive 
unit must not be exceeded. The safe operation can only be ensured if used as specified.  

 

 

Target audience of these installation instructions 
These installation instructions are geared towards qualified persons trained in the handling 
of door systems. Expert knowledge, relevant skills and practical experience are what set 
apart qualified persons. They are capable of safely carrying out the tasks involving 
installation, maintenance and modernisation according to the instructions. 
 

 

Safe operation 
The safe operation of the product can only be ensured if it is used as specified. Follow the 
installation instructions. Observe all specifications, especially warnings, when installing the 
product in the overall system. GfA is not liable for damage resulting from non-observance 
of the installation instructions. The resulting overall system must be reassessed for its 
safety in accordance with applicable standards and directives (e.g. CE marking). These 
installation instructions refer only to a part of the overall system and are not sufficient as 
the sole instructions for the overall system. The installer of the system must prepare the 
instructions for the overall system. We recommend entering the danger area of the system 
only when the drive unit is at a standstill. 
 

 

 

Содержание 10003195 00001

Страница 1: ...f Installation Instructions ELEKTROMAT ST 80 24 50 00 Model 10003195 00001 en Status 14 02 2022...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...12 7 Completing commissioning inspection 13 8 Disposal 15 9 Declaration of incorporation Declaration of conformity 16 Symbols Warning Potential injury or danger to life Warning Danger to life from el...

Страница 4: ...experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The...

Страница 5: ...Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if...

Страница 6: ...4 Temperature range 20 40 60 2 C Operating sound pressure level 70 dB A Maximum output speed OPEN CLOSE for frequency inverter operation 42 42 min 1 Cycles per hour 12 8 3 1 h 1 Max load 80000 N Braki...

Страница 7: ...ceeded even for maximum holding or locking torque observe technical data Connection elements Use self locking connection elements with a minimum strength of 800 N mm2 8 8 Use a screw that precisely fi...

Страница 8: ...8 Mounting 4 boreholes are provided for mounting...

Страница 9: ...h sufficient load carrying capacity for installation tasks Adequate space around the adjusting screw must be ensured for the safe activation of the slipping clutch Notice Gearbox damage from shortenin...

Страница 10: ...03 175 Nm Warning Injury or danger to life possible Disconnect the electrical voltage for the setting of the slipping clutch The slipping clutch acts as an overload protection The factory setting for...

Страница 11: ...ised Observe the applicable regulations and standards Make the electrical connection according to standard Use suitable tools Performing electrical installation Remove the cover Insert the motor plug...

Страница 12: ...onnection BAMA010006_Z001 X13 U V PE W N Y1 G1 C1 U1 U2 W1 W2 V1 V2 U V W PE M1 U2 W2 U1 V1 W1 V2 F10 G1 Half wave rectifier M1 Motor X13 Motor plug Y1 Magnetic brake 6 Limit switch connection F10 The...

Страница 13: ...ted Protect the output shaft permanently against corrosion Mounting Check that all connection elements consoles torque mounts screws locking rings etc are secure and in proper condition Electrical wir...

Страница 14: ...t be observed In an environment that can affect the coefficient of friction of the brake pad atmosphere with oil solvents detergents etc class of protection IP65i must be adopted Note Engage a qualifi...

Страница 15: ...se of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough po...

Страница 16: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fo...

Страница 17: ...17...

Отзывы: