General safety information 

 
Specified use 
The drive unit is only intended for vertically moving sectional doors with full counter-
balancing.  

 

The drive unit must be protected against moisture and aggressive environmental 
conditions (such as corrosive substances). The drive units are only suitable for indoor use. 
Appropriate protective measures must be taken for outdoor installation. The drive unit is 
not intended for hazardous areas. The values specified in the technical data of the drive 
unit must not be exceeded. The safe operation can only be ensured if used as specified.  

 

 

Target audience of these installation instructions 
These installation instructions are geared towards qualified persons trained in the handling 
of door systems. Expert knowledge, relevant skills and practical experience are what set 
apart qualified persons. They are capable of safely carrying out the tasks involving 
installation, maintenance and modernisation according to the instructions. 
 

 

Safe operation 

The safe operation of the product can only be ensured if it is used as specified. Follow the 
installation instructions. Observe all specifications, especially warnings, when installing the 
product in the overall system. GfA is not liable for damage resulting from non-observance 
of the installation instructions. The resulting overall system must be reassessed for its 
safety in accordance with applicable standards and directives (e.g. CE marking). These 
installation instructions refer only to a part of the overall system and are not sufficient as 
the sole instructions for the overall system. The installer of the system must prepare the 
instructions for the overall system.  
We recommend entering the danger area of the system only when the drive unit is at a 
standstill. 
 

 

 

Содержание 10002204 10012

Страница 1: ...f Installation Instructions ELEKTROMAT SE 14 21 25 40 Model 10002204 10012 en Status 26 03 2021...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...switch connection 14 9 Emergency manual operation rapid hand chain operator 15 10 Completing commissioning inspection 17 11 Declaration of incorporation Declaration of conformity 18 Symbols Warning Po...

Страница 4: ...d practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe op...

Страница 5: ...third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out i...

Страница 6: ...holding torque 600 Nm Maximum door weight 6000 N Supply voltage 3 400 V Operating current 1 90 A Operating frequency 50 Hz Power factor cos 0 56 Maximum movement per hour 16 h 1 Class of protection I...

Страница 7: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Страница 8: ...8 Mounting Eight threads are provided for mounting Use at least 2 of these Keys are used to connect to the door shaft Use a key that is at least as long as the hollow shaft 8 x M8x16 BAGAD01001_Z002...

Страница 9: ...manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thor...

Страница 10: ...t BAGAE01003_Z003 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE01006_Z002 25 Nm Secure the keys versi...

Страница 11: ...are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Inse...

Страница 12: ...12 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Страница 13: ...13 6 Motor connection M1 Motor X13 Motor plug 7 Alternative motor connection M1 Motor X13 Motor plug...

Страница 14: ...14 8 Limit switch connection F10 Thermal contact S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage...

Страница 15: ...ency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 124...

Страница 16: ...16 Switch on by pulling the red handle Open or close by pulling the chain Switch off by pulling the green handle...

Страница 17: ...ion cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good electric contact Emergency manual operation Check the function with...

Страница 18: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fo...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: