background image

 

 

 

 

 

2

 

Technical data 

Designation 

 

Unit 

Output speed 

15 

rpm 

 

 

Output torque 

300 (300) 

1)

 

Nm 

Output / hollow shaft 

40,00 

mm 

Series 

SG 85R 

Limit switch range 

(maximum revolutions of the output / hollow shaft)

 

20 

Supply voltage 

3N~ 400 

Operating current 

2,95 

Operating frequency 

50 

Hz 

Power factor cos φ 

0,58 

Safety circuit 

24 

Degree of protection 

IP 54 

Temperature range 

-20 / +40 (+60) 

2)

 

°C 

Operating sound pressure level 

< 70 

dB(A) 

 

 

Maximum output speed OPEN / CLOSE 

for frequency inverter operation

 

26 / 26 

min

-1

 

 

 

Cycles per hour 

10 (4,2)

1)

 

h

-1

 

 

 

Max. load 

30000 

 

 

Braking torque 

130 

Nm 

Braking voltage 

103 

V DC 

Rectifier type 

B1 230/103 

 

 

 

1) Specification in ( ) according to EN 60335-2-103.

 

 

 

 

2) When using a temperature range of +40°...+60°C use half of maximum cycles per hour. 

 

 

 

 

Temperature Extension! 

 

If the magnetic brake will be continuously supplied the drive can be fitted into areas 
down to a -20°C ambient temperature. 

 

 

 

Содержание 10003373 00006

Страница 1: ...f Installation Instructions ELEKTROMAT ST 30 15 40 00 Model 10003373 00006 en Status 14 02 2022 ...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 D 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de ...

Страница 3: ...n 12 7 Completing commissioning inspection 13 8 Disposal 15 9 Declaration of incorporation Declaration of conformity 16 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required action Schematic representations are based on product examples Deviations from delivered products are possible ...

Страница 4: ... experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The safe operation of the product can only be ensured if it is used as specified Follow the installation instructions Observe all specifications especially warnings when installing the product in the ove...

Страница 5: ... Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if the drive unit is subjected to impermissible forces Inadmissible forces examples collision with a forklift dropping the drive unit tearing or pulling on the motor lead to damage to the drive unit The...

Страница 6: ...54 Temperature range 20 40 60 2 C Operating sound pressure level 70 dB A Maximum output speed OPEN CLOSE for frequency inverter operation 26 26 min 1 Cycles per hour 10 4 2 1 h 1 Max load 30000 N Braking torque 130 Nm Braking voltage 103 V DC Rectifier type B1 230 103 1 Specification in according to EN 60335 2 103 2 When using a temperature range of 40 60 C use half of maximum cycles per hour Temp...

Страница 7: ... maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter to the full Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions BAGAC03301_Z002 ...

Страница 8: ...8 Mounting Four holes are provided for mounting BAGAD03301_Z002 ...

Страница 9: ...e sure to use a lifting device that has a sufficient load carrying capacity Ensure that there is sufficient space around the handwheel for safe operation of the friction clutch Notice Gearbox damage from shortening the output shaft If you cut off the output shaft the built in slipping clutch cannot be adjusted The gearbox cannot generate any torque The gearbox will be damaged Do not shorten the ou...

Страница 10: ...otential injury or danger to life Disconnect the electric supply to set the friction clutch The friction clutch provides overload protection It is tightened finger tight at the factory Turning to the right handwheel or screw increases the transferable torque Turning to the left decouples the drive unit from the door does not apply to version with floor release BAGAE3303_Z002 ...

Страница 11: ...ergised Observe the applicable regulations and standards Make the electrical connection according to standard Use suitable tools Performing electrical installation Remove the cover Connect the motor cables and brake cables BAHAA17_Z001 BAHAB08_Z001 Completing the electrical installation Mount the cable entries and or cable glands ...

Страница 12: ...12 5 Motor connection G1 Half wave rectifier M1 Motor Y1 Magnetic brake 6 Limit switch connection F10 Thermal contact ...

Страница 13: ...cted Protect the output shaft permanently against corrosion Mounting Check that all connection elements consoles torque mounts screws locking rings etc are secure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good electric contact ...

Страница 14: ...st be observed In an environment that can affect the coefficient of friction of the brake pad atmosphere with oil solvents detergents etc class of protection IP65i must be adopted Note Engage a qualified engineer to check the drive unit annually Apply shorter inspection intervals for doors that are operated frequently Observe the applicable regulations and standards ...

Страница 15: ...ose of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough postage to the package and mark it as old devices Notice Environmental damage The gearbox contains oil Ensure proper disposal according to local legal regulations ...

Страница 16: ... complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 11 1 5 13...

Страница 17: ...17 ...

Отзывы: