![GF JRGURED LF 1319 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/gf-0/jrgured-lf-1319/jrgured-lf-1319_operating-and-maintenance-instructions-manual_2219256029.webp)
E
29
Operating range
The pressure-reducing valve
JRGURED LF
is
approved for the following operating ranges:
Identification
- 1/2 – 2 1/2 (DN/valve size)
-
JRGURED LF
(name of the valve)
- JRG (manufacturer’s trademark)
- Flow direction arrows
- LF (low lead brass)
Factory setting
The pressure-reducing valve
JRGURED LF
are
set at the factory to the following outlet pres-
sures:
Type
1319
56 psi
Type
1339
80 psi
Other pressure settings on request.
Operating and maintenance instructions
Before commissioning the pressure-
reducing valve, the inlet line has to be
thoroughly flushed out.
Commissioning:
Slowly open the shut-off valve
upstream of the pressure-reducing
valve.
The pressure-reducing valve
JRGURED LF
is
ready for operation.
JRG Code
PN
p
sec
t
max
psi
psi
°F
1319
357
28 – 85
158
1339
357
80 – 140
158