Cable plan
TSA 160 WC-compartment
for the handicapped
3
1 1
3
1
3
3
4
3
4
3
4
3
4
2
8
3
4
3
4
3
4
*1
Main
switch
Power supply line
230V/50Hz
Fuse 16 A
Connected load
2 x 200 W
Emergeny
cut-off
switch
Key-operated
switch,
exterior
Contactor,
exterior
Programme
switch
(lockable),
exterior
Door opener,
lock switch
contact
Contactor,
interior
“OCCUPIED“
change-over
switch with
lamp 24 V/80
mA, interior
Lamp
“OCCUPIED“
24 V/80 mA,
exterior
In addition:
Wiring diagram 70423/9-9750
Auxiliary wiring diagram WC-control70712/9-961
Allow cable to protrude at least 1 m out of the wall
IMPORTANT:
The breaker contact must be installed in close
proximity to the door and must not be concealed by
the open door
Note:
Any warranty and service agreements will
be rejected if GEZE products are combined
with third-party products.
Cross-sections of cable
1
= NYM-J 3x1,5 mm²
2
= J-Y(ST)Y 2x4x0,6 mm
3
= J-Y(ST)Y 2x2x0,6 mm
Positioning of the movement detectors
Sensor strips
TSA160
Wiring diagram TSA 160 WC-
compartment for the handicapped
single-leaf
230 V 50 Hz
Sketch A