TSA 160 NT
20
Contact sensor outside
7.2 Radar movement detector GC 304 R
à
The GC 304 R is a direction-sensitive radar movement
detector.
à
Upon activation, the output of the GC 304 R is closed
(24V applied to the KI input).
X
Follow the installation instructions.
X
Setting the contact type parameter:
à
DPS: Set
cl
to
01
(factory setting).
à
ST220: Set “Signals”, “Input signals”, “KI” and “KI
contact type” to “normally opened contact”
(factory setting).
à
S1, S2: Set parameter 13 to 01 “normally opened
contact” (factory setting).
WH
YE
BN
GN
80 mA
- UB
+UB
GC 304 R
1
2
3
4
5
24V
KI
GND
2
21
1
KI
7.3 Push button (potential-free normally opened contact)
à
Setting the contact type parameter:
à
DPS: Set
cl
to
01
(“normally opened contact”)
(factory setting).
à
ST220: Set “Signals”, “Input signals”, “Contact sensor
inside” and “Contact sensor inside, contact
type” to “normally opened contact”
(factory setting).
à
S1, S2: Set parameter 13 to 01 “normally opened contact”
(factory setting).
21 KI
2 24V
KI
8
Contact sensor outside
à
The input contact sensor outside is only active in the AU operating mode.
à
In the case of 2-leaf systems the contact sensor outside can be connected to the active leaf control or to the
passive leaf control.
à
On selection the active leaf opens and, if switched on, the passive leaf.
à
For the input KA an activation delay (
aa
, “KA delay”) can be set. The connection of a closing position limit switch
is necessary for this (see chapter “Closing position monitoring, closing position blanking SIS, Push And Go“).
This time is added to the general activation delay time (
Dl
, “Opening delay”).
Setting the parameters:
à
DPS: Set
aa
to the desired delay time (0 s ... 10 s).
à
ST220: Use the buttons
or
to set “Signals”, “Input signals”, “KA”, “KA delay” to the desired delay time
(0 s … 10 s) and press
.
à
S1, S2: Set parameter 16 to the desired activation delay (00 s … 10 s).
8.1 Radar movement detector GC 302 R
à
For information see GC 302 R (KI).
à
Upon activation, the output of the GC 302 R is closed
(24V applied to the KA input).
à
Setting the contact type parameter:
à
DPS: Set
cO
to
01
(factory setting).
à
ST220: Set “Signals”, “Input signals”, “Contact sensor
outside”, “Contact sensor outside, type
of contact” to “normally opened contact”
(factory setting).
à
S1, S2: Set parameter 15 to 01 “normally opened
contact” (factory setting).
WH
BU
BK
BN
50 mA +UB
-UB
GC 302 R
1
2
3
4
5
24V
KA
GND
2
23
1
KA