TS 5000 E
GB 4
Mounting and securing
Mark out and drill fixing holes for door closer and guide rail using fitting template or cut M5 thread
X
if necessary.
Drill additional hole (A) for 24V DC power supply.
X
In case this product is in use with an hold-open device, please observe the document “Instructions for
Installation, Commissioning, Operation and Maintenance of the GEZE Hold-Open Device FA GC” as well.
Mount guide rail and end caps
6.2
Fig.: 6.2.1
The cable connection must point to the pull side.
Align spacers on guide rail (
X
1.).
Fix guide rail in place (tightening torque: 2 Nm) (
X
2.).
Align end caps and screw it on (
X
3.).
Mount door closer according to instructions (
X
4.).
All screwing torques are to be adjusted on site, if necessary.
Mount sliding lever and connect with sliding block
6.3
Connect sliding lever with door closer (tightening torque 14 Nm) (
X
1.).
Connect sliding lever to sliding block. Tightening torque: 5 Nm (
X
2.).
Fig.: 6.3.1