Slimdrive SL NT GGS / Slimdrive SL NT-FR GGS
4
Safety notices
à
Observe the latest versions of directives, standards and country-specific regulations, in particular:
à
VDE 0100, Part 610 "Installing Electrical Power Systems with Nominal Voltages up to 1000 V"
à
AutSchR "Directive for automatic windows, doors and gates" (for Slimdrive SL NT-FR GGS)
à
Accident-prevention regulations, especially BGV A1 "Principles of prevention" and DGUV provision 3 DA "Im-
plementation instructions for the accident prevention regulations for electrical systems and equipment"
à
DIN EN 60335-2-103 "Safety of electrical devices for home use and similar purposes; special requirements
for drives, for gates, doors and windows"
3.3 Safety-conscious working
à
Secure workplace against unauthorised entry.
à
Watch swivelling range of long system parts.
à
Never carry out work with a high safety risk (e.g. installing the drive, cover or door leaf) while alone.
à
Secure the hood/drive panels against falling.
à
Use only the cables prescribed in the cable plan provided. Ground the shields in compliance with the wiring
diagram.
à
Secure loose, internal drive cables with cable ties.
à
Before working on the electrical system:
à
disconnect the drive from the 230 V mains and check to ensure that it is not supplied with power.
à
disconnect the control unit from the 24-V rechargeable battery.
à
note that if an uninterruptible power supply (UPS) is used, the system will still be supplied with power de-
spite the fact that the power supply is disconnected.
à
Always use insulated wire-end ferrules for wire cores.
à
Attach safety stickers to glass leaves (Mat. no. 081476).
à
Danger of injury with opened drive. Hair, clothing, cables, etc. can be drawn in by rotating parts.
à
Danger of injury caused by unsecured crushing, impact, drawing-in or shearing spots!
à
Danger of injury due to broken glass!
à
Danger of injury due to sharp edges in the drive!
à
Danger of injury during installation through freely moving parts!
3.4 Inspection of the installed system
Measures for safeguarding and prevention of pinching, impact, shearing or drawing-in spots:
à
Check the functioning of safety sensors and movement detectors.
à
The detection field of the movement detector in the direction of the emergency exit must cover the opening
width x 1.5 m in front of the door.
à
The movement detector in the direction of the emergency exit (see AutSchR) must detect people moving
faster than 0.1 m/s.
à
Check protective earth connection to all metal parts that can be touched.
3.5 Environmentally conscious working
à
When disposing of the door system, separate the different materials and have them recycled.
à
Do not dispose of batteries and storage cells with household waste.
à
Comply with the statutory regulations when disposing of the door system and the batteries and storage cells.