GEZE GmbH is referred to as GEZE below.

2.1  Intended use

The sliding door system is used for the automatic opening and closing of a building passage. 

The sliding door system may only be used in a vertical installation position and in dry rooms within the permitted 

application area.

The sliding door system is designed for pedestrian traffic in buildings. 

The sliding door system is not designed for the following uses:

 

à

for industrial use

 

à

for area of application which do not serve pedestrian traffic (such as garage doors)

 

à

on mobile objects such as ships

The sliding door system may only be used:

 

à

in the modes of operation provided for by GEZE

 

à

with the components approved/released by GEZE

 

à

with the software delivered by GEZE

 

à

in the installation variants / types of installation documented by GEZE

 

à

within the tested/approved area of application (climate / temperature / IP rating)

Any other use is considered non-intended and will lead to the exclusion of all liability and warranty claims to GEZE.

2.2  Safety notes

 

à

Intervention and modifications which influence the safety technology and functionality of the sliding door 

system may only be carried out by GEZE.

 

à

Problem-free and safe operation assumes proper transportation, proper set-up and installation, qualified 

operation and correct maintenance have taken place.

 

à

The relevant accident prevention regulations and other generally recognised safety technology or health  

& safety rules must be kept.

 

à

Only original accessories, original spare parts and accessories approved by GEZE guarantee problem-free 

function of the sliding door system

 

à

The mandatory installation, maintenance and repair work must be performed by properly trained personnel 

authorised by GEZE.

 

à

The country-specific laws and regulations are to be observed during safety technology tests.

 

à

If unauthorised changes are made to the system, GEZE cannot be held liable in any way whatsoever for any 

resulting damage, and the statement of approval for use in escape and rescue routes is no longer valid.

 

à

GEZE does not accept any warranty for combinations with third-party products.

 

à

Only original GEZE parts may be used for repair and maintenance work.

 

à

The connection to the mains voltage must be completed by an electrician or specialised electrical technician. 

Perform the power connection and protective earth connection test in accordance with VDE 0100 Part 600.

 

à

Use an on-site 10-A overload cut-out as the line-side disconnecting device.

 

à

Protect the display programme switch against unauthorised access.

 

à

In compliance with Machinery Directive 2006/42/EC, a risk analysis must be performed and the door system 

identified in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.

 

à

Observe the latest versions of guidelines, standards and country-specific regulations, in particular:

 

à

DIN 18650: “Building hardware – Powered automatic doors”

 

à

VDE 0100, Part 600: “Installation of low-voltage systems”

 

à

EN 16005: “Power operated pedestrian doorsets – Safety in use– Requirements and test methods”

 

à

EN 60335-1: “Household and similar electrical appliances - Safety Part 1: General requirements” 

 

à

EN 60335-2-103: “Household and similar electrical appliances - Safety: Special requirements for drives for 

gates, doors and windows” 

 

à

Do not loosen screw-fitted , electrical ground connections.

The product should be installed or incorporated in such a way that effortless access to the product is guaranteed 

during any repairs and/or maintenance, and that any removal costs do not stand out of proportion to the value 

of the product.

Содержание Powerdrive PL

Страница 1: ...Powerdrive Product family EN Pre installation instructions 192474 01...

Страница 2: ...ps 7 4 5 VP Kit bill of material 7 5 Pre mounting 8 5 1 Machining the track and cover 8 5 2 Preparing the track 8 5 3 Installing stop buffers 9 5 4 Connecting the contact on the toothed belt locking o...

Страница 3: ...itional Information X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Revisions and validity Version 01 valid for Po...

Страница 4: ...and repair work must be performed by properly trained personnel authorised by GEZE The country specific laws and regulations are to be observed during safety technology tests If unauthorised changes...

Страница 5: ...unsecured crushing impact drawing in or shearing spots Risk of injury due to sharp edges on the drive and door leaf Risk of injury during installation through freely moving parts 2 4 Environmentally...

Страница 6: ...er bespoke 150 105 90 70499 2 0247 Component drawing Track perforated 70485 2 0200 Component drawing Track bespoke PL 2 leaf 70485 2 0251 Component drawing Track bespoke PL 1 leaf The diagrams are sub...

Страница 7: ...lide to open 1 leaf left hand slide to open 4 5 VP Kit bill of material 1 Cover fixing 2 Transformer ground 3 Transformer 4 Transformer cable 5 Deflection pulley 6 Cable guide 7 Track 8 Control unit 9...

Страница 8: ...k profiles for damage X X Cut the track and cover to the required length see machining drawings Chapter 4 1 X X Check whether additional bore holes are necessary see machining drawing for bespoke trac...

Страница 9: ...f installation 5 4 Connecting the contact on the toothed belt locking optional X X Remove the screws 2 on the feedback switch 1 of the tooth belt locking mechanism X X Place the alarm contact switch 3...

Страница 10: ...ction pulley measured from the middle U2 Position of the motor gear unit UR Position of the deflection pulley measured from the side Vrs Extension left Vls Extension right When the drive is extended V...

Страница 11: ...ormer and control unit X X Make sure that cables are cut to length and routed in such a way that they do not become jammed when the cover is positioned and cannot come into contact with moving compone...

Страница 12: ...ide DCU 4 to the control unit X X Guide the transformer cable 1 between the control unit 2 and track 5 Alternatively the transformer cable 1 can also be mounted on the front of the control unit X X Fi...

Страница 13: ...into the control unit 4 2 3 4 Powerdrive PL FR X X Route the rotary encoder cable 2 motor connection cable 3 and motor connection cable of the second motor gear unit 1 to control unit X X Insert the...

Страница 14: ...tooth belt locking mechanism 1 in at the control unit 2 1 2 X X Lay the cable for tooth belt locking mechanism 1 through the cable guide to the tooth belt locking mechanism optional 3 shorten if nece...

Страница 15: ...trate the anodised layer of the track 5 11 Fitting the cover earthing X X Screw the cable shoe of the cover earthing cable 6 using a countersunk screw 3 serrated washer 4 and hexagon nut 5 to the cove...

Страница 16: ...8 x 13 countersunk tapping screws 3 X X Screw the threaded pins 5 completely into the retaining blocks 4 from below 2 5 4 X X Glue the side cover panels 7 to the side plates 2 on the outside with 4 g...

Страница 17: ...1 is plugged in the pulley on the motor gear unit may move suddenly X X Do not reach into the area of moving parts X X Check whether the rechargeable battery cable 1 is long enough X X If necessary pl...

Страница 18: ...etween the PE line of the mains cable and the metal part contacted with the probe is tested in each case Use the probe to contact at least the following test points Transformer metal bracket PE connec...

Страница 19: ...Powerdrive product family 19 Device safety test and production test...

Страница 20: ...geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office india...

Отзывы: