13
Special installation situations
GC 342 safety sensor
X
Cut the door transmission
cable to the correct length.
X
Strip the 8 wires and connect
them in accordance with the
wiring diagram.
X
Heed the polarity of the power
supply.
-UB
+UB
COM
+
SIO
60 mA
Test
SIS
GC 342
BGS
BN
GN
YE
WH
PK
GY
BU
RD
SIO
13
1
GND
2/4
2/4
24V
10 TST
SIO
SIS
11
1
GND
24V
10 TST
SIS
GC 342
BS
3
à
For compliance with EN 16005 and DIN 18650, the test output of the door
control must be wired and able to test the sensor.
à
The sensor is tested with GND.
X
Disable ECO-mode for connection to a GEZE Powerturn.
7
Special installation situations
7.1
Installation on fire protection doors/glass doors
If a cable cannot be routed through the door, both sensors are connected
individually to the door control.
X
Use GC 342 accessories.
SIO
13
1
GND
2/4 24V
10 TST
SIO
-UB
+UB
COM
+
SIO
60 mA
Test
SIS
GC 342
BN
GN
YE
WH
PK
GY
BU
RD
SIS
11
1
GND
2/4 24V
10 TST
SIS
-UB
+UB
COM
+
SIO
60 mA
Test
SIS
GC 342
BN
GN
YE
WH
PK
GY
BU
RD
Содержание GC 342
Страница 1: ...EN Installation and operating instructions GC 342 safety sensor 167391 03 47 0159 V3 12 19...
Страница 9: ...9 Installation GC 342 safety sensor 1 2 2 mm 5 mm 2 PZ2 3...
Страница 11: ...11 Installation GC 342 safety sensor DIP ON 1 2 3 4 1 2 6 DIP ON 1 2 3 4 PZ1 1 2 7...
Страница 19: ...19 Parameter setting GC 342 safety sensor SIO SIS SIS SIS SIS SIO SIS SIS SIS SIO SIS SIO...