TECHNICAL FILES
GWA1521
C
ATEGORY
:
General loads actuator
S
UPPLY VOLTAGE
:
230V AC / 50Hz
O
UTPUT CONTACTS
:
1 NO 10A (AC1) 230V AC
N
O
.
OF OUTPUT CHANNELS
:
1
M
AX
.
DISPERSIBLE POWER
(W):
2W
M
AX
.
MOTOR POWER
:
500W
O
UTPUT POWER
:
3 dBm
CFL
LAMPS
:
150W
L
OADS CONTROLLED BY TOROIDAL TRANSFORMERS
:
450W
L
OADS CONTROLLED BY ELECTRONIC
TRANSFORMERS
:
600W
230V
HALOGEN INCANDESCENT LAMPS
:
2300W
230V
LED
LAMPS
150W
D
EGREE OF PROTECTION
:
IP20
O
PERATING TEMPERATURE
:
[-5°; +45°C]
S
TORAGE TEMPERATURE
:
[-25°; +70°C]
R
ELATIVE HUMIDITY
(
NON
-
CONDENSATIVE
):
Max. 93%
D
IMENSIONS
L
X
H
X
D
(
MM
):
42x40x20
C
OMMUNICATION PROTOCOL
:
ZigBee (IEEE 802.15.4)
R
EFERENCE
S
TANDARDS
:
2014/53/EU
GWA1502
C
ATEGORY
:
Contact interface
S
UPPLY VOLTAGE
:
230V AC
– 50 Hz
I
NPUT VOLTAGE
:
230V AC
O
UTPUT POWER
:
8 dBm
N
O
.
OF INPUT CHANNELS
:
2
M
AX
.
CABLE LENGTH
:
/
D
EGREE OF PROTECTION
:
IP20
S
TORAGE TEMPERATURE
:
[-25°; +70°C]
O
PERATING TEMPERATURE
:
[-5°; +45°C]
R
ELATIVE HUMIDITY
(
NON
-
CONDENSATIVE
):
Max. 93%
D
IMENSIONS
L
X
H
X
D
(
MM
):
42x40x20
C
OMMUNICATION PROTOCOL
:
ZigBee (IEEE 802.15.4)
R
EFERENCE
S
TANDARDS
:
2014/53/EU, EN 60669-2-1, EN 60669-1, ETSI EN
300-328
Содержание Chorus GWA1521