background image

English

21

GewaTel 200 • User Guide

Keypad tone

Keypad tone

On

Off

Press Menu.

Select menu for Settings.

Press OK.

Select keypad tone.

Press OK.

Choose whether the keypad tone should be 

On/Off using the up/down key.

Press OK.

Note! 

Even if the pad keytone is switched 

off, the tones are still heard when you dial a 

number.

...

Svenska

English

Menu

Select language

Press Menu.

Select Language menu.

Press OK.

Select language using the up/down key.

Press OK. 

Содержание GewaTel 200

Страница 1: ...User Guide Speaker phone GewaTel 200 English ...

Страница 2: ... Guide This package contains the following items 1 x User guide 1 x Speaker phone 1 x Mains transformer 1 x Power supply and network cable Tele plug Please check the contents If any items are missing please contact your retailer ...

Страница 3: ...calls Programming R key Speed dial redial Volume control mute function adjusting Menu Add new number and IR channel to phonebook Edit phonebook Delete names and numbers Auto Answer Answer button IR control of keypad Adjusting ring volume Adjusting date and time Selecting languages Key pad tone Reset Accessories and spares Troubleshooting and maintenance Technical data 4 5 6 7 8 8 8 8 9 9 10 11 12 ...

Страница 4: ... 200 User Guide Description Output earphones Microphone inputs Analogue telephone connection POTS Top Bottom Display Speaker Green red microphone indicators Microphone IR receiver for remote control Keypad Power supply ...

Страница 5: ... 0 1 space point 2 A B C Å Ä Á À a b c å ä á à 3 D E F É È d e f é è 4 G H I g h i 5 J K L j k l 6 M N O Ö Ø Ñ m n o ö ø ñ Display and keyset Time Date Call meter OK key Menu key R key Up down key Mute key Delete key Shift key The above keys can be programmed for control by an IR transmitter ...

Страница 6: ...ine Connections on the bottom of GewaTel 200 Only the following makes of mains transformer may be used FRIWO type FW7237 12 or Perfekt 2042 2043 Helms Man DEN4824129 ML120P070G ED4824120070P and DBN4824129 UK Analogue line 100 240 V electrical output Mains transformer Connection ...

Страница 7: ...an connect a telephone with a handset headset to the same telephone socket as your GewaTel 200 Note that GewaTel 200 s tele plug must be the first plug in the telephone socket Transfer the call between the handset headset telephone and the GewaTel 200 by pressing the OK key ...

Страница 8: ...must be programmed to the relevant function see different section for this GewaLink channels 00 61 63 127 can be used Incoming calls with Auto Answer Incoming calls A ring signal will be heard and the green microphone indicators light up to indicate the incoming call After the phone has rung six times the subscriber making the call will hear an answer tone The subscriber making the call must enter...

Страница 9: ...ress any of the IR transmitter keys that are programmed in the telephone Press OK to end the call Incoming calls with Answer key 0 9 0 9 Outgoing calls Press OK Dial the number Dial the number first to check it Press OK The number is called after approx 3 seconds The call duration is displayed in the call meter display Press OK to end the call or 12345 12345 or ...

Страница 10: ...s R then 3 and all three of you can participate in the call If your call is not answered Press R then 1 to return to the first call 1234567 1234567 Calls Note The availability and function of three party calls can vary between countries but also different types of PBX that GewaTel 200 is connected to If you wish to connect multiple participants we recommend that you contact an operator who offers ...

Страница 11: ...g is 2 Check in the table below if it applies to you Value Time R1 65 ms R2 100 ms R3 150 ms R4 270 ms R5 600 ms R6 80 ms Press OK to finish and save the value R function R2 If the R key does not function The PBX requirements for R key function varies between PBXs and different countries GewaTel 200 therefore offers the possibility of programming the time so that it will function with most PBXs on...

Страница 12: ...the call Calls Retrieving speed dial numbers Press up down to scroll through the phonebook in alphabetical order The last dialled number appears first in the list Press OK to dial the selected number The number is displayed and called after approx 3 seconds Press OK to end the call Alternative If the IR transmitter is programmed for speed dial one can ring directly by one press on the IR transmitt...

Страница 13: ...itch to green Tuning When GewaTel 200 is switched on the sound is adjusted for the room and telephone line automatically GewaTel 200 sense the room s acoustics and continually adjusts during the call For manual tuning the up down key is pressed at the same time Static is briefly heard Volume control mute function tuning Volume control Adjust the volume during the course of the call using the up do...

Страница 14: ...then enter the next letter read the description of the characters that can be used on page 5 Press OK Press a key on the IR transmitter key on the IR transmitter that controls the speed dial If you do not want to enter an IR channel continue with the next step Memory full is displayed if you attempt to save more than 50 numbers IR used is displayed if you attempt to store an IR channel that has al...

Страница 15: ...ress OK Edit the number using the keypad Press OK Edit the name using the keypad Press OK Press a key on the IR transmitter If you do not want to change an IR channel continue with the next step IR used is displayed if you attempt to enter an IR channel that has already been stored Press OK Press the shift key to enter lower case letters Press the C key to delete a letter or a digit Press the Menu...

Страница 16: ...ss OK Select Erase Press OK Select the name you want to delete from the list Press OK to select Erase is displayed If you do not want to delete press C If you want to delete press OK The selected name and number is erased Delete names and numbers Company Ltd Erase PHONEBOOK Erase ...

Страница 17: ... and press 1 for Active or 2 for Inactive Alternative Active Select and press 1 to change the code or press 2 to continue Alternative Code Enter a 4 digit code Press OK Select Return to exit programming or continue and make other settings Press OK Auto Answer means that the telephone answers automatically when the calling subscriber enters a code Auto Answer Return 1 Code 1234 2 Continue ...

Страница 18: ... GewaLink channels that are programmed in the telephone or only one answer button Only applies to incoming calls Press Menu Select menu for Settings Press OK Select Gewa Setup Press OK Select Answer button Press OK Press 1 for One or 2 for All Select Return to exit programming or continue and make other settings Press OK Menu ...

Страница 19: ...61 63 63 127 can be used Press Menu Select menu for Settings Press OK Select Gewa Setup Press OK Select IR setup Press OK Select and press key on the telephone keypad Select and press key on the IR transmitter IR used is displayed if you attempt to store an IR channel that has already been stored Keep the C key held in to finish Select Return to exit programming or continue and make other settings...

Страница 20: ...nth Press OK Select year Press OK Select hour Press OK Select minutes Press OK Time and date is saved Go back using the C key Menu Adjusting the ring signal volume Press Menu Select menu for Ring signal volume Press OK Adjust the volume using the up down key If the symbol with the crossed bell is selected the ring signal is switched off Press OK The ring signal volume is saved ...

Страница 21: ...keypad tone Press OK Choose whether the keypad tone should be On Off using the up down key Press OK Note Even if the pad keytone is switched off the tones are still heard when you dial a number Svenska English Menu Select language Press Menu Select Language menu Press OK Select language using the up down key Press OK ...

Страница 22: ...annels and other settings are reset to the factory settings Press Menu Select menu for Settings Press OK Select Gewa Setup Press OK Select Reset Press OK Select Reset IR KBD keypad Reset all IR Reset all or Cancel Press OK Press 1 for Reset or 2 for Cancel Select Return to exit programming or continue and make other settings Press OK 1 Reset 2 Cancel Gewa Setup Reset Return ...

Страница 23: ...racket 160010 Earphones Spares Part no Description 160055 Power supply and network cable 7 5 m 160060 Transformer 12 V DC 160062 Transformer UK 12 V DC Tele plugs Part no Description 160072 Denmark 160073 Finland 160074 France 160075 Germany 160076 Great Britain 160077 Netherlands 160071 Norway 160078 Spain 160070 Sweden 160079 Switzerland ...

Страница 24: ... bottom of GewaTel 200 3 Bypass any extension cables and check if the GewaTel 200 works properly If not contact your retailer 4 Disconnect the expansion microphones and check if the GewaTel 200 works without them If not contact your retailer 5 If the GewaTel 200 needs to wait for a second dialling tone you should enter a pause using the pause mute key when entering a telephone number as an instruc...

Страница 25: ...used Room echo reduction 208 ms Line echo reduction 25 ms Automatic adjustment 1 ms impulse cannot be presensed Earphones output 3 5 mm telejack IR channels GewaLink 00 61 63 127 Dimensions Diameter 232 mm Weight 700 g Temperature range 5 40 C in operation Relative humidity 20 80 condensation free EMC EN 50 081 1 1992 EN 55 024 1998 EN 60950 Electrical safety EN 60950 Telecom approval EUROPEAN TBR...

Страница 26: ...on microphones accessories Power supply Power from microphone output Cabling Modular 4 4 contacts 2x1 5 m and 2x2 5 m Microphone Omni directional Microphone indicator Green microphone on Red microphone off Temperature range 5 40 C in operation Keypad 3 keys ...

Страница 27: ...English 27 GewaTel 200 User Guide ...

Страница 28: ... SE 191 22 Sollentuna Sweden Tel 46 0 8 594 694 00 Texttel 46 0 8 594 694 18 Fax 46 0 8 594 694 19 E mail info gewa se Web www gewa se Part no 808565 Doc Manual GewaTel 200 DK DE GB FR NL NO SE Ver D Date 2008 09 30 ...

Отзывы: