4.5. General
Data
4.5.1. Electrical supply
The
e-Brick
requires a 3-Phase mains supply with a Protective Earth connection (3P+E);
no neutral connection is made. Refer to Table 6 for operating Voltage range and peak supply
current per phase.
Power factor is typically 0.9 for all
e-Brick
variants so no additional power factor correction
is required.
e-Brick
variant
Nominal
Supply
Voltage
Absolute
Maximum
Voltage
Peak current
/ phase (A)
Supply
Frequency
Maximum
Power
9kW 415V 374-528V
20
50-60Hz
<9.6kW
12kW 415V
374-528V
25
50-60Hz <13.1kW
22kW
415V
440V
374-528V
57
45
50-60Hz
<24kW
Table 6: Electrical supply data
Advice!
The actual current consumption of the
e-Brick
is dependent on the supply
voltage and the power level demanded by the installation. Please contact GEW service for
the actual running current for any specific UV system configuration.
4.5.2. Performance Ratings
Refer to GEW for
e-Brick
performance data; output voltage and current are maintained for
the full operating voltage range detailed in Table 6
e-Brick
variant
Output voltage
(V)
Output current
(A)
Efficiency (%)
9kW
12kW
22kW
Refer to GEW
Table 7: Performance data
4.5.3. Noise & Vibration
The
e-Brick
contains fans to cool the power electronics, these generate some noise but this
is likely to be insignificant in the context of the environment the product is installed in.
e-Brick
variant
Fans
Noise level (dBA @ 1m)**
9kW 2
60.8dBA
12kW 4
68.2dBA
22kW 6
71.7dBA
** Measured in open environment at 1m from air intake: ambient noise level ~48dBA
GEW UV
e-Brick
installation and operating manual
21 of 49