While on GPA Display Mode, once a specific RPM threshold is
reached (i.e., 750 RPM below the limiter), all blue LEDs will flash.
This is the Shift Light indicator that suggests the rider to shift
up the gear.
NOTE: The Shift Light threshold can be edited using GET Maya
Advanced programming software (sold separately).
From “GPA Display” mode switches to “GPA Setting” mode by pressing the Mode
Button for 1 second. Release the button. Blue LEDs indicating the current GPA level
set and the red MFL light will start flashing.
NOTE: if the current GPA level is 0, only the red MFL light will start flashing.
Pressing the button makes it possible to turn the blue LEDs on in sequence to the
desired value. The LEDs will turn on progressively each time the button is pressed.
SHIFT LIGHT
GPA SETTING MODE
MFL
LC
1
10
2
3
4
7
5
6
8
9
Shift Light Mode
MFL
LC
GPA Display Mode
MFL
LC
1
10
2
3
4
7
5
6
8
9
GPA Setting Mode
MFL
LC
NEW GPA Level set
1 sec
2,5 sec
HOLD
RELEASE
If the required value is exceeded, it can still be reached by continuing to press the button
(once the maximum value is reached, the selection restarts from GPA level 0). Once
the desired level is reached, release the button.
After 2,5 seconds, the LEDs will stop
flashing, indicating that the new GPA level is set. The device will automatically switch
to the GPA display mode. A good suggestion for first users to find the ideal level of GPA
to set (it may be totally different from rider to rider) would be to start riding at level 10
and then decrease the level of GPA assistance until the level which fits more is achieved.
NOTE:
- It is possible to activate and complete the “GPA setting mode” only with engine
running below 8000 RPM and with throttle position below 10%.
- If a specific GPA level is set directly on the power maps of GET ECU, this level will
not be followed when installing LC-GPA. In this case the GPA level the maps will
follow is the one selected with the LC-GPA.
LAUNCH CONTROL MODE
MFL
LC
GPA Display Mode
MFL
LC
MFL
LC
Launch Control Mode
3 sec
2,5 sec
HOLD
HOLD
RELEASE
Activating LC Mode
From “GPA Display” mode switches to “Launch Control” mode by pressing the Mode
Button for 3 seconds. The central red LC LED will start flashing. Release the button.