Operation 

 

CONTROL PANEL  

 

 

CONTROLS 

 
Power Control 

 

 

 

 

 

The power control turns the unit on and off. 
When the plug is first plugged into a socket the machine will bleep and go into stand-by 
mode.  Pressing the “Power” button will turn the machine on.  Pressing the “Power” button 
again will put the machine back into stand-by mode. 
Note:-  After switching the unit off, wait 3 minutes before switching it on again. 

 

 

 

Warning Light 

   

 

 

 

This warning light will illuminate (Red) when the water tank within the machine is full and the 
machine will stop.   If after draining the tank, the warning light remains on, this could indicate 
that there may be a fault with the machine.   If this is the case, do not attempt to operate the 
machine and call the service number. 

 

 

Mode Control

  

 

 

 

 

The mode control has three settings  

Cool  Dehumidifier  Fan  

Repeated pressing of the mode button will select the modes in order as follows:-  
 
Cool Mode  -  LED next to the “COOL” legend will illuminate green. 
Dehumidifier Mode  -  LED next to DEHUMIDIFIER legend will illuminate orange. 
Fan Mode  -  LED next to FAN legend will illuminate yellow. 
Note:-  In Cool and Fan mode, the fan speed can be set to High, Medium and Low.  When 
Dehumidifier mode is selected the fan speed is automatically set to Medium and cannot be 
altered from this setting. 

 

Cool Mode 

In this mode the air is cooled and hot air is exhausted through the vent hose to outside the 
room.  Fan speed and temperature can be adjusted to suit the comfort level required. 

 

Dehumidifier Mode 

Air is dehumidified as it passes through the air conditioner and the damp warm air should be 
exhausted by means of the vent hose to outside of the room. 

 

Fan Mode 

Air is cooled and circulated throughout the room.  Note:-  It is not necessary for the vent hose 
to exhaust outside the room.    
 

Содержание GPACU10

Страница 1: ...USER INSTRUCTIONS FOR GET PORTABLE 8k BTU AIR CONDITIONERS MODEL No s GPACU8 and GPACU8S ...

Страница 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Troubleshooting Maintenance Energy saving tips Specification ...

Страница 3: ...lti functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying and Independent Fan control This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained yo...

Страница 4: ...is fitted with an approved BS 1363 13A 3 pin plug and a 13A BS 1362 fuse In the event of either requiring replacement ensure that equivalent rated and approved components are used See plug replacement details below 11 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air condit...

Страница 5: ...Warning In order to ensure the long reliable and safe functioning of the air conditioner the following safety points should be observed ...

Страница 6: ...Identification of Parts ...

Страница 7: ...connector are located over the two moulded fingers positioned on the diameter of the machine outlet The connector can be removed from the machine by rotating it slightly and pulling it away from the machine at the same time The exhaust nozzle should be fitted to the connector on the free end of the hose and again care should be taken to ensure that the two rectangular cut outs in the connector are...

Страница 8: ...bject Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose should not be blocked by a shutter or similar device When fitting the vent hose it should be kept as straight as p...

Страница 9: ...gs Cool Dehumidifier Fan Repeated pressing of the mode button will select the modes in order as follows Cool Mode LED next to the COOL legend will illuminate green Dehumidifier Mode LED next to DEHUMIDIFIER legend will illuminate orange Fan Mode LED next to FAN legend will illuminate yellow Note In Cool and Fan mode the fan speed can be set to High Medium and Low When Dehumidifier mode is selected...

Страница 10: ... the number of hours until it is required for the machine to start up automatically The green timer LED will continue to flash and the display will show the time set Timer Temperature Adjust buttons In Cooling or Dehumidifying mode the temperature can be manually set by pressing the Timer Temp Adjust buttons between the limits of 16 to 32 C as shown in the display panel This cannot be done in Fan ...

Страница 11: ... Drain the water tank Air conditioner runs intermittently Malfunction Surrounding temperature is too high or too low Heat exhaust hose is blocked Contact the service centre Check the hose Air conditioner functions but the room is not cooled Window or door is left open in the room There is heat source in the room or too many people in it Filter is too dirty Temperature settings are too high Close a...

Страница 12: ...tral or mild detergent Rinse the filter and allow to dry Replace the filter by sliding it down into the back of the unit Maintenance on the front panel and housing Do not use chemicals or solvents for cleaning the unit Use a damp cloth for cleaning You may use mild detergent to remove stubborn stains Storing the Unit If the appliance will not be used for a long time it is important to pull out the...

Страница 13: ...ake sure you check and clean the filter each week If the filter is not kept clean it can increase your power consumption and reduce the cooling efficiency Take note of the following points Avoid direct sun light on the unit through a window Maintain proper ventilation around the unit Avoid opening doors and windows as much as possible Avoid excess number of people in the room ...

Страница 14: ...B T U Hr Cooling capacity 2 3kW Dehumidifying capacity 1 8 L hour Coolant R 407C Timer 12 hour Air flow volume 300 m hour Dimensions in cms W X H X D 43 5 X 77 0 X 43 0 Weight N W 30kgs NOTE Waste electrical products or products containing refrigerants should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advi...

Отзывы: