background image

 

 
BUTTON FUNCTIONS 

 
POWER BUTTON  

Used for switching the unit from “Standby” to “On” and from “On” to “Standby”. 
 

TIMER BUTTON 

With the machine on “Standby”, this can be used to set the time until the machine switches “On”. 
With the machine “On”, this can be used to set the time until the machines switches back onto “Standby”. 
 

HUMIDITY LEVEL SET BUTTON 

Up (

) and Down (

) buttons used to set the required humidity level as shown by the Set Humidity Level Indicator.  

 

FAN SPEED BUTTON 

Used for selecting either High fan speed (

) or Low fan speed (

). 

  

 
 
OPERATING INSTRUCTIONS

     

 

1.  Ensure the plug on the dehumidifier is inserted fully into a working power socket.  The machine will emit an audible 

“Bleep” and will be in “Standby” mode. 

2.  It is important to ensure that the water tank is correctly positioned within the unit and that it is not full of water.  If the 

“Bucket Full” indicator is illuminated when the unit is plugged in for the first time, pull the water tank out of the unit 
slightly and push it back into it’s proper position. 

3.  With the machine in Standby mode, pressing the Power Button will turn the machine on.   

           The internal fan will start up and repeated pressing of the Fan Speed button will switch the fan between high speed 

and low speed.  The fan speed is shown on the LED display, 

 = High speed and 

 = Low speed.  

           The LED display will also show the humidity level in the room and the room temperature.   
           The desired humidity level can be set using the up (

) and down (

) buttons and the set level will be shown on the 

Set Humidity Level indicator. 

4.  If the surrounding humidity level is higher than the level set on the machine, the compressor within the machine will 

start up and any moisture in the air drawn through the machine by the fan will form as water droplets on the 
condenser within the machine.  These water droplets will eventually collect in the water tank in the front of the 
machine. 

5.  When the machine brings the humidity level in the room down to the level set on the machine, the compressor will 

switch off but the fan will continue to run. 

6.  The compressor will continue to cycle on and off, keeping the surrounding humidity level close to the level set on 

the machine. 

7. Setting 

the 

Timer 

The timer can be used to:- 

a)   Switch the machine ON after a predetermined time period of 1 to 12 hrs.    

      If this is required, the machine should be plugged into a power socket and in “Standby” mode.    
      Pressing the Timer button once will cause the timer display to flash “00”.  Each time the timer button is pressed 

whilst the display is flashing, will advance the time by one hour, i.e. “01”, “02”, “03” etc.   

      When the desired time (in hours) to “switch-on” is shown on the display do not press the timer button again.  

The time set will then be permanently displayed on the machine and the machine will switch ON after the pre-
set time has elapsed.  

  

b) 

Switch the machine OFF after a predetermined time period of 1 to 12 hrs

If this is required, the machine should be plugged in and running. 

      Pressing the Timer button once will cause the timer display to flash “00”.  Each time the timer button is pressed    
      whilst the display is flashing, will advance the time by one hour, i.e. “01”, “02”, “03” etc.   
      When the desired time (in hours) to “switch-off” is shown on the display do not press the timer button again.     
      The time set will then be permanently displayed on the machine and the machine will switch OFF after the pre- 
      set time has elapsed.  
  

Содержание DHMD163

Страница 1: ...ONS FOR PORTABLE DEHUMIDIFIERS 16 LITRE MODEL NO DHMD163 20 LITRE MODEL NO DHMD203 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE ...

Страница 2: ...o play with or climb on the machine 11 If a fault develops or if servicing is required this must only be carried out be a qualified service engineer 12 If the supply cord of this appliance becomes damaged it must be replaced by a qualified engineer 13 This appliance is fitted with an approved BS 1363 13A 3 pin plug and a 13A BS 1362 fuse In the event of either requiring replacement ensure that equ...

Страница 3: ...ng air in the room Timer setting in hours 01 to 12 This symbol shows when machine is defrosting Machine stopped due to full water tank Fan on LOW speed Fan on HIGH speed Tank Full Indicator Power Button Timer Button LED Display Ambient Temperature Ambient Humidity Fan Speed Indicator Set Humidity Level indicator Humidity Level Setting Buttons Fan Speed Button ...

Страница 4: ... machine the compressor within the machine will start up and any moisture in the air drawn through the machine by the fan will form as water droplets on the condenser within the machine These water droplets will eventually collect in the water tank in the front of the machine 5 When the machine brings the humidity level in the room down to the level set on the machine the compressor will switch of...

Страница 5: ...ted If the temperature remains below 5 C the machine should be switched off CONTINUOUS DRAINING OPTION When the dehumidifier is used in a situation where it is neither desirable nor convenient to keep having to empty the water tank there is a facility to enable the unit to be continuously drained This will allow the unit to be run continually without the need to periodically empty the water tank T...

Страница 6: ...floor as it could cause noise vibration and spillage of water Keep the unit at least 20cm from a wall to dissipate the heat Clothes may be hung no closer than 50cm above the machine It is dangerous to put any object into the intake and outlet grilles of the machine Closing doors and windows will maximise the efficiency of the unit Do not expose the unit to any sources of heat When moving or storin...

Страница 7: ...ean the filter by means of a vacuum cleaner or wash it with clean water and dry using a cloth 3 Replace the filter by engaging the bottom edge in the slots provided in the body and push the top edge inwards until it clips into place TROUBLESHOOTING If you have any minor problems with the dehumidifier check the items mentioned below before contacting the helpline Problem Possible Cause Solution Bot...

Страница 8: ... D 30 C 80 RH 20 L D 30 C 80 RH POWER INPUT 300W 350W REFRIGERANT R 134a 190g R 134a 210g PRESSURE SUCTION 12kg cm 12kg cm PRESSURE DISCHARGE 24kg cm 24kg cm OVERALL SIZE H x W x D 58 2cm x 36 2cm x 27 0cm 58 2cm x 36 2cm x 27 0cm WEIGHT 14 5kg 15 0kg OPERATING TEMPERATURE 5 C to 35 C 5 C to 35 C NOTE Waste electrical products and products containing refrigerants should not be disposed of with hou...

Отзывы: