810741-05/09-17cm (804207-08) · GESTRA AG · Bremen · Printed in Germany
Supply in accordance with our general terms of business.
Oil and Turbidity Detector TURBISCOPE
OR 52/5
OR 52/6
Important Notes
Electrical connection
To connect the light emitter/receiver, please use a screened,
multi-core control cable with a min. conductor size of 0.5
mm². For the light emitter e.g. 2 x 0.5 mm
2
and for the
receiver e.g. 4 x 0.5 mm
2
.
Connect the screen in the measuring transducer only once.
Max. line length between light emitter/receiver and measuring
transducer 50 m.
To use alarm contact 1 for an initial alarm and alarm contact
2 for the main alarm, for instance, set two different limit
values.
For condensate monitoring, alarm contact 1 can then be
used to control a three-way valve, which will discharge
the unusable condensate if the level of turbidity is too high
(alarm caused by ingress of oil or start-up protection). Alarm
contact 2 will then trigger the main alarm.
Note that alarm contacts 1 and 2 and the three-way switch-
over valve will not be switched over in the event of a mal-
function.
However, the malfunction can be included in the control
of the three-way switch-over valve as shown in the wiring
diagram
Fig. 6
.
Pneumatic valves can be actuated via solenoid valves.
Valves with a single-phase AC motor and max. power rating
of 50 VA (see wiring diagram
Fig.5
or
Fig. 6
) can also be
connected directly. Install a reversing contact in between in
the case of three-phase actuators.
Order & Enquiry Specification
GESTRA Oil and Turbidity Detector TURBISCOPE, consisting
of a measuring sensor with accessories and a measuring
transducer.
GESTRA Oil and Turbidity Detector OR 52/5, consisting of
a measuring sensor ORG 12 (grey cast iron GG-25) and
a measuring transducer ORT 6.
GESTRA Oil and Turbidity Detector OR 52/6, consisting
of a measuring sensor ORG 22 (stainless steel) and a
measuring transducer ORT 6.
Supply voltage ................................. V (230 V or 115 V).
Ancillaries
Three-way valve,
Pneumatic actuator, series 500 or
Three-way solenoid valve.
Electric actuator, series 200
Shut-off valve GAV
Non-return valve RK 86, 20 mbar opening pressure
Valve OPEN:
Fluid flows through
Valve CLOSED:
Fluid is discharged or
retained
Wiring diagram
Switch-over in the event of an alarm
Safety position
Spring to close
Wiring diagram
Switch-over in the event of an alarm or
malfunction
Malfunction
Alarm 2 Alarm 1
N
4 - 20 mA
R ≤ 500
Ω
Measuring sensor
ORG...
Measuring sensor
ORG...
Measuring transducer
ORT 6
Measuring transducer
ORT 6
Disconnecting
switch
Earthing screw in
housing
N
L
4 - 20 mA
R ≤ 500
Ω
Alarm 2 Alarm 1
Malfunction
Disconnecting
switch
Earthing screw in
housing
N
N
N
L
Safety position
Spring to close
Fig. 5
Fig. 6
Valve OPEN:
Fluid flows through
Valve CLOSED:
Fluid is discharged or
retained
GESTRA AG
Münchener Straße 77, 28215 Bremen, Germany
Telefon +49 421 3503-0, T49 421 3503-393
E-mail [email protected], Web www.gestra.de