28
Replacing the diaphragm actuator
The diaphragm actuator must be removed or
installed in the following cases:
To replace a faulty diaphragm actuator
To convert standard equipment to a diaphragm
actuator.
Replacing the diaphragm actuator
Remove the two hex nuts (34) from the spindle
(17).
Remove the lid (1) with the diaphragm actuator
(15), as described on page 25.
Take the double cone and spindle (17) out of the
body.
Remove the thermostats from the double cone,
as described on page 26.
Pull the spindle out of the double cone from
underneath.
Insert the new spindle into the double cone from
underneath.
Re-insert the thermostats in the double cone, as
described on page 26.
Insert the double cone with spindle in the body.
Fit the lid with diaphragm actuator to the body,
as described on page 27.
Screw the two hex nuts (34) onto the spindle
(17).
Tighten the hex nuts hand-tight.
Converting standard equipment to diaphragm
actuator
To convert the equipment to work with a diaphragm
actuator, proceed as follows:
Remove the lid (1), as described on page 25.
Take the double cone out of the body.
Take the thermostats out of the double cone, as
described on page 26.
Insert the spindle (17) into the double cone from
underneath.
Re-insert the thermostats in the double cone, as
described on page 26.
Insert the double cone with spindle in the body.
Fit the lid with diaphragm actuator to the body,
as described on page 27.
Screw the two hex nuts (34) onto the spindle
(17).
Tighten the hex nuts hand-tight.
Installing the equipment following repairs
After repair work, re-install the equipment as
described on page 14.