9. Repairs
Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty
period should only be carried out by
skilled technical personnel
. Failure to observe the
assembly and setting procedures and operation by non-skilled personnel may result in seri-
ous damage to the blind rivet setting tool. In case of doubt, always send the blind rivet set-
ting tool back to the supplier or to GESIPA
®
.
10. Troubleshooting
10.1 Blind rivet is not set
Cause
Corrective measures
Jaws (No. 5) dirty
Clean and oil sliding surfaces (Point 8.1)
Jaws (No. 5) worn
Replace (Point 8.2)
Insufficient working pressure
See working pressure (Point 4)
Tool stroke too low
Top up with hydraulic oil (Point 8.3)
10.2 Spent mandrel is not evacuated
Cause
Corrective measures
Spent mandrel container (No. 36) full
Empty (Point 7.5)
Wrong nosepiece (No. 1) used
Replace according to table (Point 6)
Nosepiece (No. 1) worn
Replace
Spent mandrel jammed in jaws (No. 5)
Clean jaws (No. 5) and jaw housing (No. 4)
and oil sliding surfaces; replace if worn
(Point 8.2)
8.4 Storage
The blind rivet setting tool should be stored in a dry place where there is no danger of frost.