Bezeichnung der Maschine/ description of the machine 

Druckluftbetriebene hydr. Hochdruckpumpe/ airdriven hydr. high pressure pump 

 

Typ/ type 

GERUPRESS HP26 

 

Serien-Nr./ serial-no. 

                                                                 HP26 -  

 

Maschinenrichtlinie/ machinery directive 

2006/42/EG            2006/42/EC 

 

EMV-Richtlinie/ EMC directive 

2014/30/EU 

 

Angewandte harmonisierte Normen/ applied harmonized standards 

EN12100:2011, EN 60204 

 

Bevollmächtigter techn. Dokumentation/ authorized person for techn. documentation 

Franz Lulei 

 

Friedberg, 13.06.2014 

 

Dipl. Ing. Rudolf Schroll 

Geschäftsführer/ business manager 

EC-Declaration of Conformity

  

We, the company  

GERUS Apparatebau GmbH&CO.KG 
Engelschalkstrasse 16,                          
86316 Friedberg, Germany,  

declare hereby that the following described 
machine in its conception, construction 
and form put by us into circulation is 
in accordance with all the relevant essential 
health and safety requirements of the  
following EC directives. 
 

EG-Konformitätserklärung

  

Wir, die Firma  

GERUS Apparatebau GmbH&CO.KG 
Engelschalkstrasse 16,                              
86316 Friedberg, Deutschland,  

erklären hiermit, dass die nachfolgend 
bezeichnete Maschine aufgrund ihrer 
Konzipierung und Bauart sowie in der von  
uns in Verkehr gebrachten Ausführung den 
einschlägigen Sicherheits- und Gesundheits-
anforderungen den nachfolgenden  
angeführten EG-Richtlinien entspricht. 
 

Содержание HP26

Страница 1: ...ruckpumpe HP26 Operating manual for Gerupress high pressure pump HP26 11 49015 0105 Version 2 0 Datum 19 07 2016 GERUS Apparatebau GmbH Co KG Engelschalkstrasse 16 D 86316 Friedberg e mail info gerus...

Страница 2: ...anager EC Declaration of Conformity We the company GERUS Apparatebau GmbH CO KG Engelschalkstrasse 16 86316 Friedberg Germany declare hereby that the following described machine in its conception cons...

Страница 3: ...von der Verordnung nur are only concerned by the regulation as als nachgeschalteter Anwender betroffen downstream user and therefore we are sind und daher nicht zur Registrierung not bound to registe...

Страница 4: ...tions 5 2 Instructions for use 6 2 1 How to test a high pressure pump to see if it works 6 2 2 How to work with the high pressure pump 6 3 Risk analysis 7 4 How to exchange the oil at the high pressur...

Страница 5: ...d by a security valve adjustable in the low pressure circle cf risk analysis For operating the compressed air pressure 15 bar have to be connected to the GERUPRESS the gauges have to be checked and th...

Страница 6: ...ressure control valve C to the right as far as it will go until you feel a resistance 8 Check the air pressure on the pressure gauge I There should be an air pressure of at least 6 bar 9 Put start lev...

Страница 7: ...evel in 1 cover cannot be closed wounding g Sufficient lubrication of the oil pump and providing with hydraulic oil is ensured by mounting the pump into the oil tank In case of a pump leakage the gadg...

Страница 8: ...ce and self help If the pressure at oil pressure gauge F doesn t remain constant and drops as described under point 12 the pump is not air tight or the decompression valve B is not fully closed In mos...