english
Maintenance / Troubleshooting
Fault
Cause
Remedy
Pressure drop
>
Air in the system
•
Vent the system by operat-
ing the spray gun several
times at short intervals.
If necessary, operate the
cleaner for a short time
without the high-pressure
hose connected.
> High pressure nozzle blocked
worn
•
Clean/replace the high
pressure nozzle
> Pressure control on the spray
pipe is not set correctly
•
Set the required working
pressure
>
Detergent tank empty
•
Top up detergent tank or
set detergent metering to
“0”
Pressure fl uctuations
>
Pump draws in air (only pos-
sible in suction mode)
•
Check that the suction set
is air-tight
>
Lack of water
•
Open water tap
>
Water inlet hose is too long
or its cross-section too small
•
Use specifi ed water inlet
hose
>
Lack of water caused by
blocked water fi lter
•
Clean the water fi lter in the
water connection (never
work without water fi lter)
>
Lack of water because max.
permissible suction height
has not been heeded
•
See instructions
The motor does not start when
the cleaner is switched on
>
The plug is not inserted prop-
erly, i.e. there is no current
•
Check the plug, lead and
switch and if necessary
have them replaced by a
trained electrician
>
The mains fuse is switched
off
•
Switch on the mains fuse
Recycling the cleaner
Make the old cleaner un-
usable immediately.
1. Unplug the cleaner and cut
the power cord.
Do not discard of electrical ap-
pliances with household waste.
As specified in European Direc-
tive 2002/96/EC on old electri-
cal and electronic appliances,
used electrical goods must be
collected separately and recy-
cled ecologically. Contact your
local authorities or your nearest
dealer for further information.
Guarantee
Guarantee
Our general conditions of busi-
ness are applicable with regard
to the guarantee. Subject to
change as a result of technical
advances.