background image

7

made by a certifi ed electrician and com ply with IEC 
60364-1.

• It is recommended that the electrical supply to the 

machine should include a residual current device that 
will interrupt the supply if the leakage current to earth 
exceeds 30 mA for 30 ms.

• Due to the high power consumption of the machine an 

appropriate mains fuse is required.

• Inadequate extension cables can be dangerous. If an 

extension cable is used, it shall be suitable for outdoor 
use, and the connection has to be kept dry and off the 
ground. 

• Gerni recommends use of an extension cable drum 

when cable extension is needed which keeps the 
socket at least 60 mm above the ground.

• If the electric cable is damaged, it must be replaced 

by an authorized Gerni distributor or similar qualifi ed 
person in order to avoid a  hazard.

• Connecting the high pressure washer to a supply 

system, the max allowed impedance is = 0,4023 

 

(Zmax). Consult with the supply authority that the 
equipment is connected only to a supply of that im-
pedance or less.

  

Water 

connection

• This high pressure washer is only allowed to be con-

nected with the drinking water mains, when an appro-
priate backfl ow preventer has been installed, Type BA 
according to EN 60335-2-79. 

• The backfl ow preventer can be ordered under number 

106411177. 

• As soon as drinking water has fl own through the back-

fl ow preventer, it  is no longer regarded as drinking 
water.

• Operation by suction (e.g. a rainwater vessel) is car-

ried out without a backfl ow preventer – see “

Connec-

ting to a pressureless water supply

”. The machine 

can be connected to water mains with a max. inlet-
pressure of 1 MPa/10 bars and max. 60°C.

Содержание poseidon 2

Страница 1: ...128303775 c 09 2015 Poseidon 2 User Guide...

Страница 2: ...Copyright 2015 Gerni...

Страница 3: ...5 Start and stop of the machine when connected to a water supply 13 5 6 Start the machine when connected to open containers suction mode 14 5 7 Pressure regulation on the Flexopower Plus spray lance 1...

Страница 4: ...applicable use a device in order to avoid or re duce aerosols production e g a shield covering the nozzle For protection against aerosols use a respira tory mask of class FFP 2 or higher The high wat...

Страница 5: ...ental capabilities or lack of experience and knowledge If the machine is used by people with re duced physical sensory or mental capabilities or lack of experience and knowledge they shall have been g...

Страница 6: ...y ad versely affect the function of the machine Before starting the work Inspecting the machine Do not use the machine if a supply cord or important parts of the machine are damaged e g safety de vice...

Страница 7: ...authorized Gerni distributor or similar qualified person in order to avoid a hazard Connecting the high pressure washer to a supply system the max allowed impedance is 0 4023 Zmax Consult with the su...

Страница 8: ...draw in fluids containing solvents e g gaso line heating oil paint thinner or acetone These sub stances damage the materials used in the machine Their spray is highly combustible explosive and poi son...

Страница 9: ...uld always be made in Gerni authorized workshop with original Gerni spare parts Do not attempt any maintenance not described in the instructions If the machine refuses to start stops pulsates pres sur...

Страница 10: ...rface to be cleaned or severe personal injuries 3 1 Application 3 2 Operation elements and model survey See illustration at the end of this manual 1 Start stop switch 2 Water inlet with filter 3 High...

Страница 11: ...se hook can be mounted on the front as well as on the back Front position is to be used if the product is used together with a special wall hook for wall storage 4 3 Mounting of quick coupling 1 Screw...

Страница 12: ...Only max 7 m additional exten sion hose can be added 5 2 Mounting of spray lance 1 Pull the blue quick release grip A of the spray gun backwards 2 Insert the nipple of the spray lance B into the quic...

Страница 13: ...dle press the button 14 and move the handle up wards or downwards When a click is heard the handle is in right position 5 5 Start and stop of the ma chine when connected to a water supply The spray la...

Страница 14: ...e entire High pressure Low pressure detergents 5 7 Pressure regulation on the Flexopower Plus spray lance The pressure can be regulated on the Flexopower Plus spray lance 3 Shut off the water supply a...

Страница 15: ...he detergent work for several minutes before rinsing but never let it dry on the surface be ing cleaned Note It is important that the detergents do not dry up Otherwise the surfac that has to be clean...

Страница 16: ...and activate the trigger Let the machine run until no more water runs through the spray handle 3 Stop the machine and un plug Wind the electric cable round the hooks placed on the side of the machine...

Страница 17: ...hat it is intact before re mounting it The inlet filter must always be fitted inside the water inlet pipe to filter out various impurities as they will damage the pump valves CAUTION Failure to fit th...

Страница 18: ...e to an installation higher than the amp consumption of the machine You may try without the extension cable Machine pulsating Air in inlet hose pump Allow machine to run with open trigger until regula...

Страница 19: ...lass II Class I Protection degree IP xx IPX5 Hydraulic specification Rated pressure MPa bar 12 120 Max pressure MPa bar 13 130 Rated water flow l min l hr 7 8 470 Max water flow l min l hr 8 7 520 Max...

Страница 20: ...roduct family stan dard EN 61000 3 2 2006 A1 2009 A2 2009 EMC Part 3 2 Limits Limits for harmonic current emissions equipment input current 16 A per phase EN 61000 3 11 2000 Electromagnetic compatibil...

Страница 21: ......

Страница 22: ......

Страница 23: ...12...

Страница 24: ...isk Pty Ltd Unit 1 13 Bessemer Street Blacktown NSW 2148 Phone 1300 556 710 E mail info au nilfisk com NEW ZEALAND Accent Tools Ltd 232 Bush Rd Albany Auckland 0632 Phone 09 968 2610 E mail sales acce...

Отзывы: