Read all of these instructions before plugging in or turning on the UVC Air Sanitizer

1.

2.

Remove the front cover from the machine by pulling the bottom part of the front panel toward you.

3. Remove the air filters.  Behind the filters you will find 4 UVC bulbs.  Check to make sure they are not broken and have not 

become disconnected during shipping.  Replace filters and make sure they fit snugly.  Replace front cover.

FAN SPEEDS

: You can manually adjust the 3 fan speeds by pressing the Fan Speed button until you obtain the desired fan 

speed.  Or set the sanitizer to auto and it will automatically adjust the fan speed as necessary when dirtier air is sensed. 

The lowest setting can be used as gentle white noise at night for a quiet, restful sleep.

7.

8.

TIMER

: Press the button once to set the timer to turn off the machine in 1 hour.  Press twice for 2 hours, 3 times for 3 

hours, etc.  Settings: 1-8 hours.

10. To manually turn on/off the UVC and ionizer functions individually, use the remote control (included)

9.

AUTO

: Press the button once and the fan speed will authomatically adjust for dirtier air

11. Always unplug the sanitizer from the outlet before removing cover

Be sure the sides, top and bottom of the UVC Air Sanitizer are not blocked or covered so that air can circulate in and out of 

the machine.

*

You can read more about PM2.5 and what constitutes good, moderate, and poor air quality readings at 

once to shut off auto mode

a.

b. twice to set the machine to sleep mode

c.

third time to reset to auto mode with UVC and ionizer functions off

4.

Plug the UVC Air Sanitizer into an electrical outlet.

5.

ON/OFF

: Turn on UVC Air Sanitizer using the touch screen display button or the remote control.

6.

MODE

: Press the button:

a.

When the machine first comes on, it will automatically be in Auto mode with UVC light and ionizer functions on.  

No timers are set so the machine will run continuously until you turn it off manually or set a timer function.

b. Upon start up, the air quality sensor will alternate between poor, fair and good until it filters enough air through 

the machine to obtain a PM2.5 reading.  Initially, the PM2.5 reading will register as 4 flat lines (----) until the 

sanitizer obtains a PM2.5 reading.

Instructions for Use

Display Functions/Buttons

Decibel Levels

On/Off

 – Turn sanitizer on/off 

Timer

 – Sets time to shut off sanitizer (1-8 hours)

Mode

 – Controls auto, settings

Fan Speed

 - Adjust the 3 fan speeds

Remote Control Functions (see above for explanations)

On/Off

 – Turn sanitizer on/off 

Reset

 –   Remove all user settings and reset to default settings

Timer

 –   Sets time to shut off sanitizer (1-8 hours)

Speed

 –   Adjust the 3 fan speeds

Auto

 –     Turn on/off automatic setting 

Sleep

 –    Turns on sleep mode (display off, quiet) 

UVC

 –      Turn on/off UVC bulbs

Anion

 –   Turn on/off ionizer

3 Fan 

Speeds 

Air Quality 

Display 

PM2.5 

Particulate 

Monitor 

Auto Shut-off 

1,2,8 + 12 

Hour Settings 

Touch Screen 

Controls 

Sleep Mode 

< 25 Decibles 

Temperature 

Display 

Automatically 

Adjusts for 

Dirtier Air 

Ionic Air 

Filtration 

UVC Light 

Disinfection 

Fan Speed

Mode

Timer

On/Off

AQI Good

Purify

Timer

Speed

Sleep

AUTO

Anion

UV

PM2.5

TEMPERATURE

AQI Poor

AQI Medium

F

H

UV

Fan Speeds:

Low

21db

Medium

28db

35db

High

Sanitize Rooms up to 645 square feet

EPA Co. No. 97721 

Reset

Timer

Sleep

Speed Auto

Auto

On/Off

Sterilize

Anion

Содержание ICAS

Страница 1: ...ad reports go to www germozap com Please read all warnings and instructions before using this device Save these instructions This product is intended for household use only Reset Timer Sleep Speed Auto Auto On Off Sterilize Anion FanSpeed Mode Timer On Off AQIGood Purify Timer Speed Sleep AUTO Anion UV PM2 5 TEMPERATURE AQIPoor AQIMedium F H Staphylococcus aureus ATCC 6538 ...

Страница 2: ... or lightning strike and wherever water collides like the shower a waterfall or from ocean waves It is also produced as part of the normal growth process for many plants Negative ions purify the air by magnetically attracting to pollutants until these newly formed larger particles become too heavy to remain in the air you breathe Negative ions produced by the ionizer function in this sanitizer are...

Страница 3: ...ons off 4 Plug the UVC Air Sanitizer into an electrical outlet 5 ON OFF Turn on UVC Air Sanitizer using the touch screen display button or the remote control 6 MODE Press the button a When the machine first comes on it will automatically be in Auto mode with UVC light and ionizer functions on No timers are set so the machine will run continuously until you turn it off manually or set a timer function...

Страница 4: ...be used to disinfect surfaces or objects Store in a cool dry place THIS DEVICE IS NOT A TOY KEEP OUT OF THE REACH OF CHILDREN This Large Room UVC Air Sanitizer is not a medical device It is for sanitizing only This device cannot keep users from getting sick and cannot be used to treat any illness Warnings CAUTION WARNING WARNING The ionization feature in this machine emits ozone Ozone is a gas kno...

Отзывы: