4. Clean the odor sensor housing with a soft brush or vacuum cleaner (Figure 4)

 

 
 

 

 

Important tips:

 

 

● Never use detergent or metal objects to clean the sensor;

 

● If there is no regular cleaning, it will affect the sensor sensitivity of the purifier;

 

● The cleaning frequency of the sensor varies according to the working environment of the 
purifier; in a dusty environment, the cleaning frequency should be appropriately increased.

 

 Warranty Contact: 800-977-7292 

 

This unit comes with a 1-year Warranty applicable from the date of purchase. If the following 
situations occur

—equipment failure, the device or power cord is damaged, or the device is not 

properly working

—please contact the CureUV tech support hotline at 800-977-7292.

 

 

 

 Storage: 

 

 

When you are not using the purifier for a long time, store it in a dry, cool place.

 

 

 Common malfunctions: 

 

Do not disassemble the machine yourself; improper repair may cause danger to the user!

 

Before contacting the CureUV support hotline, please check the following troubleshooting table:

 

 

Malfunction 

Checking 

Processing method 

 

 

Unable to start

 

Is the power plugged in?

 

Plug in the power supply at the correct voltage

 

Are all the lights off?

 

Press the power button to select the desired

 

function

 

Is there a power outage?

 

Device is available when power is restored

 

Are the left and right 
covers covered?

 

Install the left and right covers correctly

 

The airflow is much 
weaker than before

 

Does the filter need to 
be cleaned or replaced?

 

Check whether the filter is clean or has 
reached the replacement cycle; replace 
or clean the filter if necessary.

 

There is bad smell 
in the air outlet

 

Does the filter need to 
be cleaned or replaced?

 

Check whether the filter is clean or has 
reached the replacement cycle; replace 
or clean the filter if necessary.

 

Wind speed cannot 
change automatically

 

 

Is it manual mode?

 

 

Choose the appropriate mode of operation

 

Air quality indicator

 

does not change color

 

Whether the sensor air inlet 
is covered by dust

 

 

Clean sensor air inlet

 

 

Содержание 600 CFM Knight

Страница 1: ...ray Beach FL 33445 Toll Free 800 977 7292 Fax 561 404 7206 E mail Us Sales cureuv com GermAwayUV 600 CFM Knight UV Air Scrubber SKU 201185 Please read this manual carefully before using the product After reading please take good care of this manual for inspection ...

Страница 2: ...and keep it in a safe place The product is subject to the actual packaging and will be subject to change without prior notice Description 2 Safety precautions 2 Important matters 3 Working principle 3 Before use 3 Use 4 Maintenance 5 Storage 6 Common faults 6 Warranty 6 After sales service 7 ...

Страница 3: ...ance of the machine in advance Children should be taken good care of to ensure that they do not play with the product This product can be used for children aged eight and over people who lack relevant experience and knowledge or physical sensory or mental but they must be trained or instructed to know how to use this product safely and know the dangers involved in this product Do not use this prod...

Страница 4: ...anic gases VOCs Odor Secondhand smoke Tiny particles PM2 5 Pollen Mites Animal allergen Bacteria virus Large particle dust Hair Pet hair Note 1 For best purification please use the filter provided by CUREUV 2 Installation and disassembly of the pre filter suitable for pre filter cleaning operation Before using Select the room where you need to purify the air and place the purifier on a stable floo...

Страница 5: ...h high precision dust sensor and odor sensor which can monitor indoor air volume in real time The color change of the air quality indicator shows the air qualityin the current room In the automatic purification mode the device can automatically identify the degree of pollutionin the room and adjust the wind speed accordingly Air quality indicator light color Blue Green Yellow Red Air quality Excel...

Страница 6: ...ng after the set time Note When the display shows PM2 5 value short press this button to switch to the shutdown time display value Maintenance Before any maintenance operation be sure to use the power switch 1 Turn off the power supply and unplug it You can clean the product body with a slightly damp cloth IMPORTANT Do not use any abrasive material to prevent damage to the surface of the device Wh...

Страница 7: ...cause danger to the user Before contacting the CureUV support hotline please check the following troubleshooting table Malfunction Checking Processing method Unable to start Is the power plugged in Plug in the power supply at the correct voltage Are all the lights off Press the power button to select the desired function Is there a power outage Device is available when power is restored Are the le...

Отзывы: