Operating Instructions   

COOLING MODE 

The cooling function allows the air condit-

ioner to cool the room and at the same time

reduces the humidity in the air.

To activate the cooling function ( COOL ), press the

  MODE   button until the    pointer points to COOL.

The  cooling  cycle is activated by setting the keys 

or   at a temperature lower than that of the room.
To optimize the functioning of the conditioner, adjust

the temperature, the speed and the direction of the

oair flow by pressing the keys indicated.

“SWING ” CONTROL OF THE AIR FLOW 

 The air outlet flow is uniformly dist-

     ributed in the room. 

 It is possible to position the direction

     of the air in the optimal solution.

The deflectors are positioned manually and placed 

under the flaps .They allow to direct the air flow 

from up to down.

CAUTION!

Never position Flaps manually, the delicate mech-

anism activating them could be seriously damaged!

DANGER!

Never insert your hand or objects in the air outlet of 

the units!These units contains a fan that turns at high 

speed.

This adjustment must be done with the appliance 

switched off. 

Notes!

The horizontal Auto-Swing (left to right)  is optional.

It depends on the model.

The key        activates the

FLAP , the air flow is 

directed alternatively from left to right . In order to 

guarantee an even diffusion of the air in the room. 

SWING

 In cooling mode , orient the flaps in horizontal 

     direction; 

COOL

SWING

Содержание WAC-407R

Страница 1: ...ad these instructions and warranty information carefully before use and keep them handy for future reference U S E R M A N U A L WAC 407R WAC 409R WAC 412R WAC 418R Window Type Air Conditioner W Remot...

Страница 2: ...P 2 Table of Contents Introduction 03 Operating Instructions 04 Electrical Specifications 11 Installation Instructions 12 Care and Maintenance 15 Troubleshooting Guide 16 Warranty Terms Conditions 31...

Страница 3: ...Cover Air inlet grille Indoor Cabinet Air outlet grille Indoor Air inlet grille Outdoor Vent Lever Control Panel Air filter Fig 1 1 Control Panel For remote control model Remote Control WAC 407R WAC...

Страница 4: ...the ON TIMER is set the timer LED displays the remaining time to turn on the unit If you want to cancel ON TIMER press TIMER button 3 Everytime you press this button the air conditioner will be start...

Страница 5: ...ED on control panel No Button Function 1 Timer 2 Cooling 3 Fan only only Cooling Unit 4 Sleep 5 Display set temp Display set timer 6 Low fan speed 7 Mid fan speed 8 High fan speed 9 Auto fan speed Abo...

Страница 6: ...The unit confirms the correct reception of each press button with a beep To select the mode of operation To activate or deactivate of the movement of the ELECTORS To activate the function SLEEP Decre...

Страница 7: ...t is possible to position the direction of the air in the optimal solution The deflectors are positioned manually and placed under the flaps They allow to direct the air flow from up to down CAUTION N...

Страница 8: ...ON IMPORTANT Before proceeding with the timed start program the working mode with the key MODE 2 and the fan speed with the key FAN 3 Switch the con ditioner off with the key ON OFF To set the automat...

Страница 9: ...ote control also stores the speed that was set in the previous mode of operation In FEEL mode automatic the air conditioner auto matically chooses the fan speed and the mode of operation This function...

Страница 10: ...king of the conditioner adjust the temperature only 2 1 the speed 2 and the direction of the air flow 3 by pressing the buttons indicated To activate the SLEEP mode of operation press the the SLEEP bu...

Страница 11: ...sure whether your wall outlet is properly grounded please consult a qualified electrician 4 The rating plate on the unit contains electrical and other technical data The rating plate is located on th...

Страница 12: ...ooling Select a place where there is no obstacles near the air inlet and outlet wall thickness is less than 210mm lf the wall thickness is more than 210mm scrape the wall as shown above Make rear side...

Страница 13: ...e air conditioner with power source securely Use a fuse as below Before installation turn off the operation switch and disconnect the power cord This appliance is not intended for use by persons inclu...

Страница 14: ...condensed water You can choose back drainage or bottom drainage Back drainage using the flare nut to block the bottom drainage hole and use water outlet pipe to connect the back drainage hole pay att...

Страница 15: ...to be pulled out from right hand side Wash the air filter with water an detergent Rinse with clean water and dry it before reinstalling AIR CLEANING FILTER FRONT COVER ETC The air cleaning filter is...

Страница 16: ...all socket After a long off period and going to use the air conditioner again clean the CONDENSER at the rear and EVAPORATOR at the front fins by using a soft brush or vacuum cleaner Be careful not to...

Страница 17: ...P 17 18 19 25 26 29 30 31...

Страница 18: ...P 18 1 1 WAC 407R WAC 409R WAC 412R WAC 418R...

Страница 19: ...P 19 1 2 0 24 10 10 3 4 5 6 3 61 16 88 31 7 8...

Страница 20: ...P 20 1 2 3 4 5 6 7 8 9 LED 1 2 3 4 5 6 7 8...

Страница 21: ...P 21 COOL SWING MODE SWING COOL...

Страница 22: ...P 22 1 2 2 3 3 TIMER TIMER MODE TIMER TIMER TIMER FAN ON OFF TIMER ON TIMER OFF 1 2 3 1...

Страница 23: ...P 23 FAN FEEL DRY MODE MODE FAN FAN DRY 3 3...

Страница 24: ...P 24 SLEEP 1 ST 1 1 ST 2 1 ST 3 2 ST 2 1 ST 10 FEEL 20 23 20 26 18 26 23 2 1 2 3 MODE SLEEP FEEL SLEEP 1 2 3 1 2 3...

Страница 25: ...P 25 1 2 3 4 5 07K 09K 12K 18K 250V 3 15...

Страница 26: ...P 26 Less than 210 210mm 45 5 10m m 210mm 400mm 400mm 210mm 500mm 55mm 210mm 210mm 210mm...

Страница 27: ...P 27 100mm 0 5...

Страница 28: ...P 28 5 6 7 8 9 10 13 15 14 12 16 11 1 5 6 7 2 2 8 3 4 11 15 16 5 10 6 12 7 8 7 13 8 14...

Страница 29: ...P 29 15 16 40 T1 18 43 T3 25 52...

Страница 30: ...P 30 50 1 2 3 4 1 2 3 500mm 4 5 6...

Страница 31: ...l 852 2333 6249 Fax 852 2356 9798 Email repairs germanpool com 1 8 852 2333 6249 852 2356 9798 repairs germanpool com Warranty Terms Conditions Under normal operations the product will receive a 1 yea...

Страница 32: ...uted Hong Kong Room 113 Newport Centre Phase II 116 Ma Tau Kok Road Tokwawan Kowloon Hong Kong Tel 852 2773 2888 Fax 852 2765 8215 116 2 113 China Tel 86 757 2980 8308 Fax 86 757 2980 8318 3 F Takshun...

Отзывы: