German pool SH-09 Скачать руководство пользователя страница 15

 

Clean

 the air filter

(a)

(b)

Clean and care

Caution

Turn power off and pull out the power plug before cleaning air conditioner, or it may cause

 electric

shock.

Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause

 an

electric shock.

Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a

dry soft cloth, or a cloth slightly moistened with water or cleanser.)

Clean the front panel

Clean the air filter (Recommended once every three months)

NOTE: If dust is much more around the air conditioner, the air filters should be cleaned many times.

After

 taking off the filter, don't touch the fin of indoor unit, in order to avoid hurt your fingers.

Take down the air filter

At the slot of surface panel to open an angle, pull the air filter

downward and take it out, please see the Fig. 4(a, b).

To clean the dust adhering to the filters, you can either

use a vacuum cleaner, or wash them with warm water

the water with the neutral detergent should below 45

degree) ,and dry it in the shade.

NOTE: Never use water above 45    to clean, or it can

cause deformation or discoloration. Never parch it by

fire, or can cause a fire or deformation.

Insert the air filter

Reinsert the filters along the direction of arrowhead, and

then to cover the cover and clasp it.

Fig.4

When cleaning the front panel, please dip the cloth into the water temperature of 45     below, 

then to dry

the cloth and wipe the dirty part.

Note: Please do not to immerse the front panel in water, due to there are microcomputer components

 and

circuit diagrams on the front panel.

12

Содержание SH-09

Страница 1: ......

Страница 2: ......

Страница 3: ...t as unsorted municipal waste Collection of such waste separately for special treatment is necessary The products in this manual may be different with the real one according to different models some m...

Страница 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 6: ...ty will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Страница 7: ...temperature range Maximum cooling Maximum heating Indoor sideDB WB o C Outdoor sideDB WB o C 32 23 27 43 26 24 18 The operating temperature range outdoor temperature for cooling only unit is 18 43 fo...

Страница 8: ...it Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Cool Dry Fan Heat Set...

Страница 9: ...rature setting Press it to decrease temperature setting FAN Press it to set swing angle TIMER ON TIMER OFF CLOCK Blow page 9 TEMP page 9 TURBO page 9 SLEEP page 9 Press it to turn on off the light LIG...

Страница 10: ...ation mode icon AUTO COOL DRY FAN or HEAT is only for heat pump models will show 15 is displayed when pressing the up down swing button Press this button again to clear the display 18 Up down swing ic...

Страница 11: ...that goes from AUTO to then back to Auto Auto Low speed Medium speed High speed Press this button to set up down swing angle which circularly changes as below OFF 1 2 3 4 5 6 Operation of Remote Contr...

Страница 12: ...els SLEEP Press this button to go into the SLEEP operation mode Press it again to cancel this function This function is available in COOL HEAT Only for models with heating function or DRY mode to main...

Страница 13: ...ote controller will not be used for a long time please Otherwise it may cause malfunction remove batteries to prevent batteries from leaking The operation should be performed in its receiving range It...

Страница 14: ...ght off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this sig...

Страница 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Страница 16: ...ct the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cl...

Страница 17: ...em still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is runn...

Страница 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Страница 19: ...mething into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very low that will s...

Страница 20: ...t to the other place please firstly contact with the authorized Maintenance Center in the local area Notices for installation Important Notices Basic Requirements For Installation Position Install in...

Страница 21: ...ional The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading 6 Notices for installation Safety Requirements For Electric Ap...

Страница 22: ...able earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places that professional personnel consider them unreliable 5 In...

Страница 23: ...Air outlet side Space to the floor Above Above Above 15cm Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above Above The dimensions of the space necessary...

Страница 24: ...pe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should...

Страница 25: ...off the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Страница 26: ...te Take off cord anchorage Connect and fix power connect cord for heat pump type connect and fix power connect cord and signal control wire to terminal block Fix the power connection cable with cord a...

Страница 27: ...e It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely It may cause electric malfunction or damage the part Has the unit b...

Страница 28: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Страница 29: ...dditional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection p...

Страница 30: ...Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m 6 9 5 or 12 20 15 20 6 or 9...

Страница 31: ......

Страница 32: ...d without prior authorization from German Pool violators will be prosecuted Hong Kong Sole Agent China Sole Agent 116 2 4 Room 2 4 Upper G F Newport Centre 116 Ma Tau Kok Road Tokwawan Kowloon Tel 852...

Отзывы: