P.13
P.12
Ventilation requirements
(Figure shows the ventilation and cut-out requirements for the installation of the appliance into a
standard kitchen unit).
Installation Instructions
(Figure shows the ventilation and cut-out
requirements for the installation of the
appliance into a tall housing unit).
Remove rear panel
from this section
40-50 mm cut out to be made in the
rear of the support shelf
Plinth
False drawer front to be fitted
515mm
45-50mm
515mm
Storage space
Storage space
Rear panel
Rear panel
Remove rear
panel from
this section
Plinth
Minimum ventilation cut-out 80 cm squared
Ensure that the oven has been securely fixed into the
housing unit. The fixing of the oven into the housing is made
by using four screws. These should be screwed through the
oven cabinet and into the housing unit.
Cooling fan
•
A tangential cooling fan is fitted inside of this appliance, to make the internal temperature of the
oven stable and the external surface temperature lower.
•
After you have finished cooking and switched off the oven, the cooling fan will continue to run
for a period of time afterwards. The length of time will depend on how long the oven has been
switched on for and at how high a temperature.
Installation Instructions
Electr
ic Ov
en EVC
-173
100
150
200
250
50
C
°