German Light Products IMPRESSIONX4S Скачать руководство пользователя страница 5

                                                                     

GLP 

 German Light Products GmbH

 

 

impression X4 S manual (v1.3) 

from software version: v1.16

 

1.1 

Safety Instructions  

 

 

The

 

 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

S

S

 

 

is a High-Tech Product. To guarantee a 

smooth operation, it is necessary to respect the following rules. 

The  manufacturer  of  this  device  will  not  take  responsibility  for 
damages  through  any  disregard  of  the  information  provided  in 
this manual. Warranty claims also will be voided in the case that 
the fixture housing is opened.  

1.  Before  powering  on  the  fixture,  make  sure  that  the  fixtures  fans  and  air 

inlets are clean and not blocked.  

2.  Ensure that the fixture head can rotate unhindered throughout its complete 

range of pan and tilt movement. A safety distance of at least 0.5 m must be 

maintained  between  the  fixture  and  any  easily  inflammable  material  (e.g. 

decoration material).  

3. 

Attention!

 

Don’t  touch  the  fixture  during  the  operation.  This  can  cause 

injuries and/or damages.  

4. 

The  fixture  doesn’t  contain  any  user  serviceable  parts.  Opening  the 

fixture will void all warranties.

 

5.  It  is  necessary  to  wait  at  least  15  minutes  after  disconnecting  the  mains 

power before handling the fixture.. Pay attention to possible hot parts of the 

fixture.  

 

       

-- Danger of BURNING --

 

6. 

Never  look  directly  into  the  beam  of  light  or  into  one  of  the  LEDs.

 

Never  use  optical  apertures  to  observe  the  beam  of  light. 

LED  Class  2M.

 

You'll risk serious injury of your eyes and in particular of your retina.

 

 

 

Attention:

  LED  Class  2M  can  cause  injuries  of  your  eyes  even 

without optical instruments in front of them or within a distance of 
less than 0.5m and short exposure time.

 

 

Hence: Avoid direct radiation into your eyes!  

7.  To  ensure  safe  operation,  follow  also  the  Installation  guide  described  in 

chapter 2. Operating the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

S

S

 

 

without suitable safety aids like 

Safety  cables  or  clamps/hooks  can  increase  the  risk  of  an  accident  and 

must be avoided. 

8.  Repair,  maintenance,  and  installation  work  shall  be  done  by  qualified  or 

GLP certified staff only.  You need to pay attention to the common rules of 

technology that are not explicitly mentioned in this manual.  

9.  Use only original GLP spare parts. Any structural modification of the system 

will terminate all warranty claims. 

10.  Please keep this instruction manual for future reference.  

 

Содержание IMPRESSIONX4S

Страница 1: ...from software version V1 16 support glp de www glp de Instruction Manual ...

Страница 2: ...GLP German Light Products GmbH impression X4 S manual v1 3 from software version v1 16 2 Notes ...

Страница 3: ... Position 9 2 3 Securing the Fixture 10 2 4 Connections 10 2 4 1 Power Supply 10 2 4 2 NEUTRIK powerCON 10 2 4 3 DMX 11 3 The Menu Field 11 4 DMX Channel Selection DMX Protocol 14 4 1 Normal Mode 18 DMX channels 14 4 2 Compress Mode 14 DMX channels 16 4 3 High Resolution Extended Mode 19 DMX Channels 17 5 5 Maintaining and Cleaning the I IM MP PR RE ES SS SI IO ON N X X4 4S S 19 5 1 Safety regulat...

Страница 4: ...ice 1 Moving head actively and passively cooled 2 Arm of device 3 LCD Display Menu data entry 4 Base with various connectors air in outlets and mounting system 5 Fuse holder 2x Base sideview 6 Mains Out powerCON 7 DMX Output 5 pin 8 DMX Input 5 pin 9 Mains In powerCON 1 2 3 4 5 base side 1 6 7 base side 2 8 9 ...

Страница 5: ...s necessary to wait at least 15 minutes after disconnecting the mains power before handling the fixture Pay attention to possible hot parts of the fixture Danger of BURNING 6 Never look directly into the beam of light or into one of the LEDs Never use optical apertures to observe the beam of light LED Class 2M You ll risk serious injury of your eyes and in particular of your retina Attention LED C...

Страница 6: ...void these possible problems please adhere to the following requirements Do not expose the front of a fixture to direct sunlight or any other strong light sources For outdoor applications during daylight make sure that the front face of any fixture is either shielded or points away from the sun even when fixtures are not in use Do not modify the front glass or lenses of any fixture These requireme...

Страница 7: ...Pay attention to the regulations of BGV C1 former VBG 70 DIN VDE 0711 217 and BGI 810 3 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X X4 4S S standing on the floor sideways or hanging different connectors are available Through this a safe and firm installation is assured You ll find dedicated M10 threads on the bot...

Страница 8: ... Please pay attention to an even and gripping surface 2 2 2 Mounting in hanging position To operate the I IM MP PR RE ES SS SI IO ON N X X4 4S S in a hanging position please use a half coupler clamp This can be mounted directly to the bottom side of the fixture It should be attached centrically with a M10 mm thread bolt max length 11mm Attention Never use a longer bolt as this may damage the inter...

Страница 9: ...ached with M10 mm thread bolts max length 11mm This technique is necessary to cope with the torque which accrues in this mounting position Never use the Mounting in hanging position technique described above to fasten the fixture in the sideways position A safe and sound installation cannot be assured in this way In addition this can damage the fixture base 2x half couplers fan outlet must be faci...

Страница 10: ... VA W T2A 2x micro fuse 5x20mm Please also see the printing on the case Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 4 2 NEUTRIK powerCON The I IM MP PR RE ES SS SI IO ON N X X4 4S S is fitted with NEUTRIK powerCON locking 3 conductor AC connectors Up to max 30 i im mp pr re es ss si io on n X X4 4S S can be linked via the power outlets ...

Страница 11: ...he Up Down keys Push the Enter key to get in the next menu level or to confirm your settings Make them and set functions ON OFF with the Up Down keys Confirm and save it with the Enter key the display shows OK Push the Mode key to cancel the entry and go back to the main menu To lock or unlock the keys of the menu field press Mode Enter Up simultaneously DOWN UP MODE ENTER Level1 Level 2 Level 3 L...

Страница 12: ...set Pan Offset Calibration for Pan offset Tilt Offset Calibration for Tilt offset LED 100mA 1A adjust Adjust dimming of the LEDs LED adjust White adjust red Adjust intensity for red channel White adjust blue Adjust intensity for blue channel White adjust green Adjust intensity for green channel Clear EEPROM Erase EEPROM memory BL Diagnose Diagnose of Boot loader Diagnose Diagnose fixture functions...

Страница 13: ... Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for Color Mixing unit Tilt Instantaneous value for Tilt Self test program Initiates a self test program Live time On time of fixture Set DMX Mode Select the desired DMX Mode Compressed Mode Fixture works in Compressed mode see also section 4 unterhalb Normal Mode F...

Страница 14: ... Effect 3 slow fast 129 223 81 DF 51 88 Random colors slow fast 224 255 E0 FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 White Color mixing system White 0 100 0 255 00 FF 0 100 10 Shutter Shutter closed 0 15 00 0F 0 5 5 Shutter pulse random slow fast 16 47 10 2F 6 1...

Страница 15: ... 40 5F 26 37 PAN TILT inverse size phase see PAN 96 127 60 7F 38 50 Circle size phase see PAN 128 159 80 9F 51 62 Circle inverse size phase see PAN 160 191 A0 BF 63 75 Lying eight size phase see PAN 192 223 C0 DF 76 87 Random movement size phase see PAN 224 255 E0 FF 88 100 15 Speed Pan Tilt movement speed from controller 0 1 00 01 0 0 5 Pan Tilt Pan Tilt slow fast Use this channel also for the sp...

Страница 16: ...7 78 7F 47 49 5 Rainbow Effect Stop 2 128 80 50 Rainbow Effect 3 slow fast 129 223 81 DF 51 88 Rainbow Effect random colors slow fast 224 255 E0 FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 White Color mixing system White 0 100 0 255 00 FF 0 100 10 Shutter Shutter ...

Страница 17: ...32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 95 97 5 Shutter open 251 255 FB FF 99 100 14 Dimmer coarse Dimmer 0 100 0 255 0 FF 0 100 15 Dimmer fine Dimmer Low 0 255 0 FF 0 100 16 Zoom Spot Flood 0 255 00 FF 0 100 17 Special Pattern Blo...

Страница 18: ... predefined colors see also point 1 before Locking and unlocking the Control Panel Please lock and unlock the control panel by pressing the menu keys MODE ENTER UP at the same time Additional Display Indications As a default you ll find the following additional information in the first row of the LCD display Vxx xx xx xx x e g V1 16 10 16 NN NS NS DMX Mode Normal Dimmer Mode Soft NN Pan Mode Norma...

Страница 19: ...will also allow the fixture to operate reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used 5 1 Safety regulations Pull out the mains power plug Wait min 15 minutes after disconnecting power to allow the fixture to cool down 5 2 Maintenance and Interval rule of thumb The contaminat...

Страница 20: ...posite of each other on the topside of the base In order to attain access you first need to remove one of the two plastic side covers of the fixture arm Open the two screws no 1 shown in the picture below Replace the fuse s with one with the exact rating as printed in this manual or the body of the fixture Never use a different one Attach the side cover again before operating the fixture 2 1 1 2 2...

Страница 21: ...e 50 000 h Wavelength optimized for maximum presentable color space Optical System Full RGBW High efficient Collimator cluster Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effects Continuous Dimmer 0 100 Zoom 7 to 50 degree continuous zoom Optical Patterns Several pre defined beam patterns with direct access and manipulation DMX Cont...

Страница 22: ...GLP German Light Products GmbH impression X4 S manual v1 3 from software version v1 16 22 7 Dimensions 224 Ø150 5 70 177 190 253 Ø165 5 7 3x M10 length max 11mm 89 44 5 Fixture from below ...

Страница 23: ...xtended Mode 17 L LED Class 2M 5 M Maintenance 19 Menu Field 11 Micro fuse 10 Mode key 11 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 9 Mounting on the Floor 8 N NEUTRIK powerCON 10 Normal Mode 14 O Optical parts 19 P Pan Movement 21 plano convex lenses 6 Power Supply 10 R RESET 14 S Safety distance 7 Safety information 6 Safety Instructions 5 Secure the Device 10 Softw...

Страница 24: ...GLP German Light Products GmbH impression X4 S manual v1 3 from software version v1 16 24 ...

Отзывы: