GeoVision GV-COM Скачать руководство пользователя страница 2

2006.01

Installing GV-COM Drivers

When you connect GV-COM to the computer, the Found New Hardware Wizard will 
automatically detect the device. Ignore the wizard, and follow these steps to install 
the drivers.

1.

Insert the installation CD to your computer.

2.

Run 

GvUsb.exe

3.

When this warning window appears, click 

Continue Anyway

.

The drivers will be installed automatically. 

To verify the drivers are installed correctly, go to Device Manager.  Expanding the 
Ports field, you should see one entry for

 Prolific USB-to Serial Bridge

Long-Distance Connection

When the two conditions below are met, the supplied Terminal Resistor needs to 
be used:

1. Connection distance is greater than 600 meters
2. High-speed baud rate is applied, ex. 115200.

The diagram below illustrates how to use Terminal Resistor on Terminal Block 
attached to the RS-485 device:

RS-485+

RS-485-

RS-485+

RS-485-

GV-COM

PTZ, GV-Data Capture, etc.

GeoVision GV-DATA CAPTURE

GeoVision GV-COM

Terminal Resistor