1.0 General safety precautions

IMPORTANT- Read the entire manual before installing 

and use.

 

Retain this manual for future reference and instruct all 

users in the function and usage of the product.

Do not detach factory fitted parts as it will hinder the 

operation of the filter.  

Power cords and pressure hoses must be replaced 

immediately if they are damaged. This work must be 

carried out by a trained professional.  

All electrical connections must be carried out by a  

trained electrician. 

1.1 Hazard

Dismounting parts of the Dustbox is associated with 

danger. 

When fitting or servicing the Dustbox, it must be 

 

 disconnected completely. 

1.2 Area of application

The Geovent Dustbox is used for filtering of 

 

contaminated air from industrial processes such as: 

welding smoke, grinding and sanding.

 

The Dustbox CFU-1000 filter is not to be used in areas 

which require the use of ATEX certified products. 

The Geovent Dustbox CFU-1000 is supplied with a filter 

cartridge. (filtration efficiency: min. 99,90% according to 

BIA-test.)

Cleaning of the filter is manual. A shot of pressurized 

air is sent through the filter cartridge loosening the par

-

ticles attached to the fabric of the cartridge. 

 

It is recommended that the filter shot valve is released 

after each use. Press the button on the side of the filter 

to release the valve.

1.3 Technical specifications

Compressed air: 

Max. 3,5 bar - clean and dry air

Air consumption: 

3,0 liter/min.

Power supply:  

24VDC el. 230VAC (standard)

Temperature: 

-12°C - +65°C (extracted air)

Corrosion Class: 

III

Duct sealing: 

Class C

 

Temperature extracted air 

Max 65°C

Temperature surroundings:     -40°C - +40°C

Operating relative humidity:  <90%

Differential pressure Geovent Dustbox CFU-1000

Typical pressure drop: 

1000-1500 Pa

The pressure drop over the filter will vary according to 

work load and how dirty the filter cartridge is.

 

When the pressure drop reaches 1800 Pa the filter 

cartridge must be replaced.

Differential pressure can not exceed 

1.800 Pa.

 

1.4 Construction

Housing:  Warm Galvanized steel.

 

(Corrosion class lll), with connection.

Compressed air tank: Powder coated steel

Collection drawer: Galvanized – up to 38L 

300

250

Flow [m³/h]

[Pa]

Fan MHF-400-3

2900 Rpm

500 750

1000

1250 1500 1750

2000

2250 2500 2750

600

900

1200

1500

1800

2100

2400

2700

3000

3300

3600

3900

3000

4200

MHF-500

MHF-400

Index

1.0 General safety precautions  . . . . . . . . . . . . . . . . . . 2

1.1 Hazard  

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

1.2 Area of application    . . . . . . . . . . . . . . . . . . . . . . . . 2

1.3 Technical specifications

  . . . . . . . . . . . . . . . . . . . . . 2

1.4 Construction  

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2.0 Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2.2 Test run- calibration  . . . . . . . . . . . . . . . . . . . . . . . .

4

4.0 Maintenance 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

4.1.1 Emtying the collection drawer 

. . . . . . . . . . . . . . .

5

4.1.2. Replacing filter cartridge

. . . . . . . . . . . . . . . . . . .

5

 

4.1.3. Timer setting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.2 Trouble shooting

. . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5.0 Liability

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

6.0 Declaration of conformity  . . . . . . . . . . . . . . . . . . . . 8

Содержание Dustbox CFU-1000

Страница 1: ...D U S T B O X CFU 1000 Version1 0 05 01 15 I N S T R U C T I O N S M A N U A L www geovent dk...

Страница 2: ...released after each use Press the button on the side of the filter to release the valve 1 3 Technical specifications Compressed air Max 3 5 bar clean and dry air Air consumption 3 0 liter min Power s...

Страница 3: ...Dustbox CFU 1000 is connected to circular ducts on both dirty and clean side The lower duct connection is always the dirty side Seal the duct connection using tape or rub ber seal 3 To ensure free mix...

Страница 4: ...service technician Periodic maintenance All electrical components should be checked yearly Make sure that the air supply for the compressed air system is clean and dry Otherwise the filter cartridges...

Страница 5: ...ot fitted shut off the compressor and empty the tank manually using release button 4 Unscrew all finger screws and remove the service hatch 5 The filter cartridge is held in place by three latches in...

Страница 6: ...new time is saved the unit will start operating with the new time setting Default values ON 0 2 seconds OFF 30 seconds If the desired OFF time is set then simply don t press any buttons and after a f...

Страница 7: ...user fitter must follow this In struction Manual in all respects Under no circumstances may the products be changed in any way without prior written consent from Geovent A S 4 2 Trouble shooting In ca...

Страница 8: ...VENT DK hereby declares that The product Geovent Dustbox CFU 1000 has been manufactured in compliance with the directions of the Directive Council of 14 June 1989 in common approximation to the legisl...

Отзывы: