21
V1.7 January 2021
8.0
SPECIFICATION
The above technical specification is accurate at the time of the last document
revision and is intended as guide only.
The information above is liable to change without notice and may not, therefore, be
100% accurate for the supplied sensors.
Resolution
0.05% Full Scale (readout dependent)
Sensor Accuracy
0.1% Full Scale
Thermal Effect
Less than 0.02% Full Scale per
o
C **
Thermal Operating Range
-
20 to + 80
o
C
Temperature Sensor
Thermistor ( 3k
Ω
@ 25
o
C )
Operating Range
7m (standard)
-
others available upon request
Over Range Capacity
Range + 20%
Excitation
Pluck or Swept Frequency
Standard Range* 7, 17 metres
Sensor accuracy 0.1% full scale
System accuracy Site dependent
Resolution 0.025% full scale
Temperature range
-
20°C to +80°C
MODEL DESCRIPTION
VWPS
-
201V VW vented pressure sensor 70 kPa
VWPS
-
202V VW vented pressure sensor 140 kPa
VWPS
-
203V VW vented pressure sensor 175 kPa
VWPS
-
204V VW vented pressure sensor 345 kPa
VWPS
-
201S VW sealed pressure sensor 70 kPa
VWPS
-
202S VW sealed pressure sensor 140 kPa
VWPS
-
203S VW sealed pressure sensor 175 kPa
VWPS
-
204S VW sealed pressure sensor 345 kPa