-4-
Caution !
In order to engage the footswitch properly, the switches on the front panel must be in the position
MIDDLE OFF and in position NORMAL pertaining to WARM.
Troubleshooting procedures.
!!! When replacing fuses the power cord MUST NOT be connected to a power wall socket !!!
In case of amp malfunction try the following steps:
1. The LED in the POWER switch does not come on. A) power cord is not plugged in power wall socket.
B) there is no power in the wall socket
C) the MAINS fuse is blown.
2. the POWER switch lights up but there is no sound. A) check if the speaker box is connected to the
amp
B) turn the MASTER JUICE and GAIN to the position 3
C) turn all frequency pods to at least position 3
3. hum can be heard but no sound. A) check if your guitar is connected to the amp and the volume knob
on the guitar is at least half way up.
B) disconnect all effect pedals
C) check the guitar cord or use a new one
If your amplifier still does not function, please see your authorized George Dennis technician.
GEORGE DENNIS Bassic Tube 120 a 200 SPECIFIKACE
Type: BASSIC TUBE 120 BASSIC TUBE 200
Power output RMS: 120 W 200 W
Power Requirements: 115/230V AC, 50/60Hz 115/230V AC, 50/60Hz
600W 600W
Effects Send/Return Impedance: 100 ? / 1 M? 100 ? / 1 M?
D.I. OUT: Max. 1,5 V RMS, 1 kHz, 600 Ohm – for both units (depending on the input signal)
Tubes: 3x ECC83, 4x E34L 3x ECC83, 4x KT88
Fuse Mains: T5A/250V pro 100-120V T,5,5A/250V pro 100-120V
version, T2,8A/250V pro version, T2,8A/250V pro
230-240V version. 230-240V version.
Fuse H.T.: T 1,5 A T 1,5 A
Foot switch: 2 Button switch Controls, MIDDLE SECTION OFF/ON, WARM OFF/ON
Dimensions: Height: 26 cm 26 cm
Width: 28 cm 28 cm
Depth: 57 cm 57 cm
Weight: 30 kg 31 kg
ELECTRICAL CONNECTIONS AND SUPPLY
WARNING:
This appliance must be earthed. Please check that the supply voltage details given on the rating
label ( located on the rear panel ) are in accordance with your electricity supply.
FITTED PLUG:
This appliance is supplied with a fitted plug. If the socket outlets in the home are not
suitable for the plug supplied with this appliance ( or the plug becomes damaged and requires replacement
), it should be cut off and an appropriate three-pin plug fitted as detailed later this in section.
IMPORTANT
: A moulded plug severed from the mains lead must be destroyed immediately. Such a plug
with a bared flexible cord is hazardous if a live socket outlet.
FUSE
: If the fuse of the moulded on plug is to he replaced, remove the coloured fuse cover on the underside
of the plug, and use a suitably certified 5A fuse approved by ASTA to B51362, i.e.-, the fuse carries the
ASTA mark. The fuse cover must always be replaced. Never use the plug cover omitted. Replacement fuse
covers are available from your local authorised service agent.