2.1.1 Hydrophones 

 
The streamer uses Geometrics’ unique proprietary polymer hydrophones.  The 
hydrophone incorporates design features offering superior performance compared to 
previous polymer hydrophone designs as well as the traditional PZT ceramic-type 
hydrophones.

  

Specifically, it is non-shattering and incorporates an isolating platform, 

making it immune to cable-borne energy.  In addition, other design aspects allow its 
response to acoustic pressure alone to dominate the output.   
 
The hydrophones are depth-limited and become inoperable at depths greater than 30 ±5 
m.  The inoperable state is temporary and functionality fully recovers when the depth is 
reduced.  This limitation allows the MicroEel to be exported under less strict US 
Department of Commerce laws.  
 

2.1.2 Hydrophone 

Preamplifiers 

 
The true differential preamplifier used with the hydrophone is of a single-pole low-cut 
and a single pole high-cut design.  The low-cut frequency is determined by the ½

π

 RC 

time constant which is related to the element capacitance and the input resistance of the 
preamplifier front-end.  The preamplifier features exceptionally low noise.  Nominal 
element capacitance is 7.2 nF at 22 degrees C.  The design also provides full voltage 
regulation at each preamplifier.  The voltage regulator isolates each channel from the 
other which is desired when all preamplifiers share a common power bus. 
 

2.1.3  Deck and Tow Cable Connector Terminations 

 
The standard topside deck cable termination is a Y-type with one 61-socket connector 
(PT06J-24-61S) for analog output, and one 4-pin connector [PT06A-8-4P(SR)] for power 
connection to the DHA-7/MicroEel Battery Pack (Figure 3).  As an option, the analog 
output termination may be ordered with a 27-socket connector(s) (NK-27-21C) instead of 
the 61-socket connector.  Adaptor cables are also available to connect to seismographs 
with other analog input connector types. 
 

MicroEel Solid Analog Streamer Operation Manual   

Page 7 of 18 

Rev. C 050612 du 

Содержание MicroEel

Страница 1: ...eamer P N 60101 13 Rev C May 6 2012 Operation Manual GEOMETRICS INC 2190 Fortune Drive San Jose CA 95131 USA Tel 408 954 0522 Fax 408 954 0902 sales geometrics com support geometrics com www geometric...

Страница 2: ...POWER SUPPLY AND REQUIREMENTS 10 2 2 1 DHA 7 MicroEel Battery Pack 10 2 2 2 Power Consumption 12 2 2 3 AC Battery Charger 12 3 SYSTEM SET UP 13 3 1 INTERCONNECTIONS 13 3 2 DEPLOYMENT 13 3 3 BATTERY C...

Страница 3: ...4 Deck cable 55 socket connector termination 8 Figure 5 Tow cable 55 pin connector termination shown with Kellems grip 9 Figure 6 Crate for transport storage and deployment 10 Figure 7 DHA 7 MicroEel...

Страница 4: ...1 MicroEel active section with solid flotation green and tow cable black In addition the MicroEel uses unique proprietary polymer hydrophones which unlike ceramic hydrophones are non shattering Polyme...

Страница 5: ...m apart 0 22 m aperture with the signal summed electrically and connected to a preamplifier For hydrophone groups less than 3 125 m there is one hydrophone per group connected to a preamplifier Other...

Страница 6: ...Figure 2 MicroEel solid analog streamer block diagram MicroEel Solid Analog Streamer Operation Manual Page 6 of 18 Rev C 050612 du...

Страница 7: ...cut and a single pole high cut design The low cut frequency is determined by the RC time constant which is related to the element capacitance and the input resistance of the preamplifier front end The...

Страница 8: ...termination not shown The standard deck cable termination for analog input from the tow cable is one 55 socket waterproof connector Glenair 220 06E16 55SN Figure 4 Figure 4 Deck cable 55 socket connec...

Страница 9: ...he connector pair between the deck and tow cables feature red marks on their collars to indicate when pin and socket are aligned 2 1 4 Cable Crate The streamer is shipped coiled in a crate for storage...

Страница 10: ...ry Pack Figure 7 contains two 12V DC deep discharge 5 Amp hour sealed lead acid batteries used in a 12V DC differential power configuration The deck cable power lead is connected to the battery pack v...

Страница 11: ...individual battery voltage and current being supplied to the streamer Figure 8 Detail of DHA 7 MicroEel Battery Pack The MicroEel is designed to be powered by the DHA 7 MicroEel Battery Pack use of an...

Страница 12: ...l vary depending on the state temperature and age of the batteries The ideal battery operation temperature is between 41 to 77 degrees F 5 to 25 degrees C Long term exposure to temperatures above 106...

Страница 13: ...ately when the minimum permissible voltage is reached 3 Connect the analog output connector on the deck cable to the seismograph and check for incoming signal It is also recommended that the seismogra...

Страница 14: ...rge cycle 2 Switch the battery pack power switch to the ON position the power switch must be ON to charge the internal batteries from the external charger The VOLTAGE and CURRENT meters will turn on a...

Страница 15: ...of time will reduce the life of the batteries Therefore it is recommended that a continuous charge be limited to no more than 1 week The battery pack will lose capacity without use A battery pack in...

Страница 16: ...ing has demonstrated that the low frequency calibration of the hydrophone is 99 99 representative of the broadband response up to 10 kHz This low frequency calibration is performed by the substitution...

Страница 17: ...to 1 m minimum Flotation Material Polyurethane based Outside Diameter 32 mm Weight in air 0 79 kg m Bend Radius 0 46 m Strength Member Kevlar center stress core Working Load 182 kg Breaking Strength...

Страница 18: ...e The limited warranty stated herein is in lieu of all other warranties expressed or implied including the implied warranties of merchantability and fitness for a particular purpose and of all other o...

Отзывы: