26
2. EDM Setting
2.1 Set the mode of EDM
Select
the
mode
of
distance
measurement,there
are
6
modes
:
Single,Repeat,Tracking,3 Times,4 Times,5 Times.
Steps
Key
Display
ƻ
1 Press [F4](
Ę
)and show
the second soft key in the
Q-Surveying. Press [F3] to
enter the interface of EDM
Setting.
[F4]
[F3]
ƻ
2 When the cursor is in
EDM mode option,Press the
direction key of
ĕė
to select
the
mode
of
measurement.Each time you
press
ĕ
or
ė
, the mode of
measurement is switched.
ĕ
ė
ƻ
3
After finishing setting,
press [F3](OK) to return the
function of Q-Surveying.If
you
want
to cancel the
settings, press [ESC] to ignore
the changes.
[F3]
Set the reflector type
Our series total station can be set up for the red laser (RL) range and invisible
infrared light (IR) range and the total station has three reflectors to be selected, which
are prism, non-prism (NP) and reflect board (Sheet). You can set by job,but the prism
used should be matched with prism constants.