3
2.2. Installation Instructions
2.2.1 Model 6160 Uniaxial and Biaxial Installation Instructions
1.
The first step is to install the uniaxial/biaxial mounting bracket (see Figure 4), which is
designed for mounting on vertical walls.
Figure 3 - Tiltmeter Mounting Bracket
Mark the location on the wall and drill, using a hammer drill, a 9.5mm (3/8") hole
approximately 37 mm (1½") deep. Clean the hole thoroughly, blowing out with compressed
air if possible. Insert the 1/4" drop-in anchor, (which has a setting pin inside it), into the
hole. The threaded end should be closest to the opening. Use the supplied ¼ inch Rawl
setting tool, and a hammer, to expand the anchor with 2 or 3 sharp blows on the setting pin.
Thread the supplied 2 inch long 1/4-20 threaded anchor rod into the anchor. Attach the
mounting bracket to the anchor rod using the supplied hardware as illustrated in Figure 4.
Use a bubble level or other leveling device to align the bracket so that the transducer
mounting face is vertical. Now tighten the 1/4-20 nut.