6
| INSTALLATION | GEOKON
TO MAKE AN ADJUSTMENT, DO THE FOLLOWING:
1.
Loosen the locking nut and then rotate the threaded rod into or out of the
end of the transducer shaft.
Note:
Grip the transducer shaft while rotating the threaded rod. Never
rotate the transducer shaft beyond 180 degrees, or gauge failure may result.
2.
After making an adjustment, align the hole in the swivel bearing over the
anchor and check the reading.
3.
Make adjustments until the desired reading displays on the readout.
4.
Push the cap screw through the swivel bearing and spacer.
5.
Tighten into the anchor.
6.
Re-tighten the locking nut.