![Geokon 4200 Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/geokon/4200-series/4200-series_instruction-manual_2214594018.webp)
8
| INSTALLING THE GAUGES IN CONCRETE | GEOKON
6.
Attach the plucking coil using a hose clamp. Tie the instrument cable off to
one of the rebar using nylon cable ties.
FIGURE 11:
Suspending Model 4200/4200L/4200HT Strain Gauges Between Rebar
4.3
ALTERNATIVE SUSPENSION METHOD
Tie two short pieces of steel rebar to the existing rebar using nylon cable ties, as
shown in the figure below. Then tie the strain gauge to the short pieces of rebar
again using more nylon cable ties. This method avoids the resonance problems
associated with the previous method.
FIGURE 12:
Alternative Method for Attaching Model 4200/4200HT Strain Gauges to
Rebar
Instrument Cable
Coil Assembly
Rebar or
Tensioned Cable
Wire Tie
Wire Tie
Rubber Tape
4200
Wire Tie
Wire Tie
Rubber Tape
Nylon Cable Tie
Instrument Cable
Short Lengths
of Rebar
Nylon Cable Ties
Nylon Cable Ties
Nylon Cable Ties