23
APPENDIX C. WIRING CHARTS
C.1 Millivolts per Volt Output
Geokon Cable
#04-375V9 (Violet)
Internal Sensor Wiring
Function/Description
Red
Red
Power +
Red’s Black
Black
Power -
White
White
White’s Black
Black
Signal -
Green
Red
Remote Sense +
Green’s Black
Black
Remote Sense -
Blue
N/C
Thermistor
Blue’s Black
N/C
Thermistor
Shields (5)
N/C
Ground
Table 6 - mV/V Output Wiring
Note:
Input voltage for Model # 3400-1, mV/V output is 10V d.c.
(Power -, Signal -, Remote Sense -, are connected internally.)
C.2 Zero to Five Volt DC Output
Geokon Cable
#04-375V9 (Violet)
Internal Sensor Wiring
Function/Description
Red
Red
Power +
Red’s Black
Black
Power -
White
White
White’s Black
Black
Signal -
Blue
N/C
Thermistor
Blue’s Black
N/C
Thermistor
Shields (5)
N/C
Ground
Table 7 - 0-5VDC Output Wiring
Note:
Input voltage for Model # 3400-2, 0–5VDC output is 6.5–35V d.c.
C.3 Four to 20 Milliamp Output
Geokon Cable
#02-250V6 (Blue)
Internal Sensor Wiring
Function/Description
Red
Red
Power +
Black
Black
Power -
White
N/C
Thermistor
Green
N/C
Thermistor
Shields (1)
N/C
Ground
Table 8 - 4-20mA Output Wiring
Note:
Input voltage for Model # 3400-3, 4–20mA output is 6.5–35V d.c.
Содержание 3400 Series
Страница 2: ......
Страница 4: ......
Страница 22: ...16 Figure 10 Typical Calibration Report for Model 3400 2 with 0 to 5 Volt Output ...
Страница 23: ...17 Figure 11 Typical Calibration Report for Model 3400 3 with 4 to 20mA Output ...