1. Press and hold the ‘Set Time’ button.
2. Press the up or down buttons to set the time.
2
Daily timed alarm
Status
Press
and
hold
Status
Up
Down
1. Press and hold the ‘Set Alarm’ button and use
the up and down buttons to set the alarm time.
2. To enable/disable the alarm at any instant,
press the ‘Alarm on-off’ button.
Status
S e
L ow B attery
3. When the alarm triggers the pillow pad will
vibrate. Pressing the ‘Snooze’ button will pause the
alarm for five minutes.
Status
Snooze
Press
and
hold
Up
Down
Status
Command options
Press and release the ‘+’ and ‘-’ buttons together,
P
Ξ0
will be shown. Press the ‘+’ button until the
desired option is displayed then press ‘Set Time’ to
select that option.
Option 1.
Set the unit to 75dB level in the 2kHz -
4kHz frequency range
Option 2.
Set the unit to 70dB level in the 2kHz -
4kHz frequency range
Option 3.
Display the battery voltage in millivolts
(6000 or higher is very good, 4000 or
lower, consider replacing the batteries)
Option 4.
Set the current alarm time to be the start
of disable period time
Option 5.
Set the current alarm time to be the end
of disable period time
Option 6
. Display disable times (start time for 4s,
followed by end time for 4s)
Option 7.
Perform a learn on the sounder (the fire
alarm must
be running before this option
is selected)
Option 8.
Alarm bell setting. Use if the alarm sound
is produced by a bell. Only select after
the learning process has been completed
(see page 4)
Setting the time