background image

14

Limited Warranty

Geo Knight & Co warrants that the press is free from defects in both material and

workmanship One Year from the date of invoice to the buyer. If any parts or workmanship are found to

be defective in manufacture, Geo Knight & Co will repair or replace the defective parts or workmanship.

In addition, Geo Knight & Co warrants that the Digital Knight heat control is free from defects in both

material & workmanship and is covered under no-charge support for (3) years. Geo Knight & Co also

warrants that the heating element is warranted for the lifetime of the press, provided it is owned by the

original purchaser. This lifetime warranty on the heating element does not cover temperature sensor

failure, damage or disconnection. This warranty covers all parts to repair the defects, except when

damage results from accident, alteration, misuse or abuse, or when the machine has been improperly

installed, or modified in any way. If the press becomes defective during the limited warranty period of

one year for the entire press, three years for the control, or the lifetime of the heating element, Geo

Knight & Co reserves the right to recall the defective press to the factory for repairs if on site component

replacement is deemed not possible by Geo Knight & Co. A return authorization must be granted by

Geo Knight & Co prior to its return.

If a press covered by the one year limited warranty must be returned to the factory for

repairs, Geo Knight & Co shall make every effort to repair buyer’s press. However, Geo Knight & Co

reserves the exclusive right to determine whether to repair or replace a defective press. If Geo Knight

& Co authorizes a replacement press, the warranty of the replacement press shall expire on the

anniversary date of the original machine’s invoice to the buyer.

There are no warranties which extend beyond the description on the face hereof. Seller

disclaims any implied warranty of merchantability and/or any implied warranty of fitness for a particular

purpose, and buyer agrees that the goods are sold “as is”. Geo Knight & Co does not warrant that the

functions of the press will meet the buyers requirements or expectations. The entire risk as to use,

quality and performance of the press lies with the buyer. In no event will Geo Knight & Co be liable

for any damages, including loss of profits, destruction of goods or any other special, incidental,

consequential or indirect damages arising from the use of the press or accompanying materials. This

limitation will apply even if Geo Knight & Co or its authorized agent has been advised of the possibility

of such damage.

Содержание Digital Knight DK20SP

Страница 1: ...1 Digital Knight 16x20 Automatic Digital Swinger...

Страница 2: ...laten Height 6 Actuating the Press 6 Guidelines Standard Settings 7 Programmable Presets 8 User Options Menu 9 Fahrenheit Celsius 9 Timer Counter 9 Recorded Pressings 9 Pressure Height Gauge Settings...

Страница 3: ...much time and effort in using this press and in your heat pressing applications Throughout this manual many areas and components of this machine will be referred to by specific names Please refer to t...

Страница 4: ...s editable in the default operating mode of the controller The left two digits of the time display are minutes The right two digits are seconds This can be changed to Hours Minutes in the User Options...

Страница 5: ...ange of the controller is from 150 F to 550 F 65 C to 288 C During the first heat up cycle of the press the controller will display 150 F 65 C until the heat platen temperature rises above that temper...

Страница 6: ...r the heat platen turn the pressure knob to the right clockwise The top head will lower toward the pressing table Actuating the Press To actuate the machine simply press both black buttons together Th...

Страница 7: ...reduce the life of the silicone pad When pressing rigid substrates plastics metals woods etc be sure that any protective films or laminates are removed before heating Always check that the transfer i...

Страница 8: ...based on the best results for every application When those presets are selected the user is immediately returned to the proper settings without time consuming experimentation and risk of unsuccessful...

Страница 9: ...renheit Celsius The Current Set Point and Preset temperature values can be displayed in Fahrenheit or Celsius To change the value to F or C use the arrow keys Press PRG to move to the next menu item T...

Страница 10: ...results of the transfer begin to deteriorate the Drop Sense feature can help the user avoid this Use the arrow keys to set the degrees or to turn this feature off If the Current temperature drops belo...

Страница 11: ...ing cycle as well as if the Drop Sense feature is enabled Use the arrow keys to change the values or to turn the alarm off Please note the different alarms below denotes a short beep _ denotes a longe...

Страница 12: ...he silver colored ring around the post that stops the head from continually swinging over the table It can be loosened and retightened when the correct position is obtained Q The control displays Err...

Страница 13: ...the way over the table and the rear limit micro switch is not being closed the press will not activate If all of these check points have been tried and the digital control is counting down but the pr...

Страница 14: ...on site component replacement is deemed not possible by Geo Knight Co A return authorization must be granted by Geo Knight Co prior to its return If a press covered by the one year limited warranty mu...

Страница 15: ...15...

Страница 16: ...16...

Отзывы: