Troubleshooting

The following information attempts to address the most probable

mechanical and user issues with the press. Most issues with heat
transfer presses are application related. That is, they have to do with
the results of a particular transfer application.

For technical support on problems having to do with the final results

of a particular transfer paper or media, please contact the supplier of that
transfer media. Generally, the machinery manufacturer is unable to support
the myriad of different transfer papers, inks and imprintable items on the
market from other resellers.

Q. The timer does not start when I close the heat platen, or the timer does

not reset when I open the press up.

A. There are several probable causes for this. The timer is activated by a

micro-tilt-sensor stuck to the pressure arm. First: When the head of
the machine is opened, the tilt sensor needs to be tilted slightly upward
to signal the controller to stop/reset. When the head of the machine is
closed, the timer sensor needs to be tilted downward (towards the
floor) to signal the controller to start counting. Second: Check the wire
connection from the tilt sensor into the control panel. The timer &
pressure signals go to a small black 6-pin connector on the top of the
circuit board in the control box. Check to make sure this is firmly
seated and plugged into the board.

Q. The control displays Err when it first comes on, and I can not set the

temperature or use the press.

A. The Err message will display if the heating signal from the platen has

been cut off, interrupted, or the heating sensor has failed. First check
the green heat connector that plugs into the digital control. This is
inside the top head. Open up the control box and unplug the green
connector at the top of the circuit board. This is the temperature sensor
wire. Remove the two wires from the green plug, cut & strip them for
fresh connections, and reconnect them to the green plug. DO NOT
SWITCH the leads - they must go to the same location on the green
plug. Make sure the wires can not be pulled out of the green plug and
then reconnect the green plug to the circuit board. Contact the factory
if the Err message continues.

Содержание Digital DK16 14x16

Страница 1: ...1 Digital Knight 16x20 and 14x16 Digital Clamshell...

Страница 2: ...elines Standard Settings 7 Programmable Presets 8 User Options Menu 9 Fahrenheit Celsius 9 Timer Counter 9 Recorded Pressings 9 Height Gauge High Point 10 Height Gauge Low Point 10 Pressure Height Gau...

Страница 3: ...s that will save much time and effort in using this press and in your heat pressing applications Throughout this manual many areas and components of this machine will be referred to by specific names...

Страница 4: ...backwards when not in use Basic Use Setting Time The time setting is always editable in the default operating mode of the controller The left two digits of the time display are minutes The right two...

Страница 5: ...ange of the controller is from 150 F to 550 F 65 C to 288 C During the first heat up cycle of the press the controller will display 150 F 65 C until the heat platen temperature rises above that temper...

Страница 6: ...e The top head will rise away from the lower table To increase the pressure turn the pressure knob to the left counterclockwise The top head will lower toward the pressing table CAUTION The heat plate...

Страница 7: ...reduce the life of the silicone pad When pressing rigid substrates plastics metals woods etc be sure that any protective films or laminates are removed before heating Always check that the transfer i...

Страница 8: ...preset Presets can be edited by pressing the TEMP key while inside the programs When the display shows SEt press the TEMP key to change the temperature time and PRS height settings for that preset The...

Страница 9: ...renheit Celsius The Current Set Point and Preset temperature values can be displayed in Fahrenheit or Celsius To change the value to F or C use the arrow keys Press PRG to move to the next menu item T...

Страница 10: ...ofout of range temperatureconditions Theusercansetthismenuitemtosoundanalarm if the heat platen drops below the Set Point temperature by the amount indicated This can be helpful when pressing substrat...

Страница 11: ...erent alarms available to choose from These alarms are sounded at the end of the timing cycle as well as if the Drop Sense feature is enabled Use the arrow keys to change the values or to turn the ala...

Страница 12: ...d be monitored to insure proper operation The pressure adjustment screw is the area of greatest wear and stress on the machine and should be checked occaisionally for loss of threading Detach the heat...

Страница 13: ...ensor needs to be tilted downward towards the floor to signal the controller to start counting Second Check the wire connection from the tilt sensor into the control panel The timer pressure signals g...

Страница 14: ...easy to replace and are a surprisingly similar or even lower cost than conventional mechanical springs Contact the factory for replacement gas springs if it is not able keep the platen open The gas sp...

Страница 15: ...to recall the defective press to the factory for repairs if on site component replacement is deemed not possible by Geo Knight Co A return authorization must be granted by Geo Knight Co prior to its r...

Страница 16: ...16...

Отзывы: