11
EN
Technical Data
Working range angle
0° - 180°
Resolution
0,1°
Accuracy angle
± 0,1°
Working range inclination
0° - 90° or 0% - 100%
Resolution
0,1° or 0,1%
Accuracy inclination
0,2°
Range of laser
20 m
Accuracy of laser
± 0,5 mm / 1 m
Laser wave length
650 nm
Laser class
2
Power supply
3 x AA alcaline
Operating time
48 h
Length (unfolded)
530 mm (1000 mm)
Weight
1,3 kg incl. batteries
POWER SUPPLY
Open the battery compartment cover on the reverse side of the
instrument and insert the batteries (ensure correct polarity). Close
the battery cover again.
Important: The battery symbol flashes if the batteries need to be
replaced.
IMPORTANT
If „error“ is displayed replace the button battery (reverse side)
immediately.
This button battery ensures the power supply when the main battery
is replaced so that the instrument will keep all calibration.
Switch off the instrument before replacing the button battery.
B
NB
When the button battery has been replaced the angle measurement
must be re-calibrated (see p. 14). Upon delivery the angle measure-
ment is correctly calibrated.